Command reference
R&S
®
ZNB/ZNBT
1299
User Manual 1173.9163.02 ─ 62
[SENSe<Ch>:]SEGMent<Seg>:FREQuency:STARt
.........................................................1306
[SENSe<Ch>:]SEGMent<Seg>:FREQuency:STOP
......................................................... 1306
[SENSe<Ch>:]SEGMent<Seg>:INSert
........................................................................... 1307
[SENSe<Ch>:]SEGMent<Seg>:INSert:SELect
................................................................ 1309
[SENSe<Ch>:]SEGMent<Seg>:PORT<PortId>:POWer[:LEVel]
.........................................1309
[SENSe<Ch>:]SEGMent<Seg>:PORT<PortId>[:STATe]
................................................... 1310
[SENSe<Ch>:]SEGMent<Seg>:POWer:GAINcontrol
....................................................... 1310
[SENSe<Ch>:]SEGMent<Seg>:POWer:GAINcontrol:ALL
................................................. 1311
[SENSe<Ch>:]SEGMent<Seg>:POWer:GAINcontrol:CONTrol
..........................................1312
[SENSe<Ch>:]SEGMent<Seg>:POWer[:LEVel]
...............................................................1313
[SENSe<Ch>:]SEGMent:POWer[:LEVel]:CONTrol
...........................................................1313
[SENSe<Ch>:]SEGMent<Seg>[:STATe]
......................................................................... 1314
[SENSe<Ch>:]SEGMent<Seg>:SWEep:DWELl
...............................................................1315
[SENSe<Ch>:]SEGMent<Seg>:SWEep:DWELl:CONTrol
................................................. 1315
[SENSe<Ch>:]SEGMent<Seg>:SWEep:GENeration
........................................................1316
[SENSe<Ch>:]SEGMent<Seg>:SWEep:POINts
.............................................................. 1317
[SENSe<Ch>:]SEGMent<Seg>:SWEep:TIME
.................................................................1317
[SENSe<Ch>:]SEGMent<Seg>:SWEep:TIME:CONTrol
................................................... 1318
[SENSe<Ch>:]SEGMent<Seg>:SWEep:TIME:SUM?
....................................................... 1318
[SENSe<Ch>:]SEGMent<Seg>:ADD
Inserts a new sweep segment using default channel settings ("Insert New Segment").
The added segment covers the frequency interval between the maximum frequency of
the existing sweep segments and the stop frequency of the entire sweep range.
Tip:
[SENSe<Ch>:]SEGMent<Seg>:INSert
to create a segment with specific
channel settings.
Suffix:
<Ch>
.
Channel number
<Seg>
Sweep segment number. Segment numbers must be sequential.
If n segments exist already, the added segment must have the
segment number n+1.
Example:
SEGM:INS 1MHZ, 1.5MHZ, 111, -21DBM, 0.5S, 0,
10KHZ
Create a sweep segment with a sweep range between 1.0 MHz
and 1.5 MHz.
SEGM2:ADD
Create a second sweep segment. The frequency range of the
second segment will be between 1.5 MHz and the maximum fre-
quency of the analyzer.
Usage:
Event
Manual operation:
See
"Add / Insert / Delete / Delete All"
SCPI command reference