Copyright 2007-2016, Auber Instruments Inc. All Rights Reserved.
No part of this manual shall be copied, reproduced, or transmitted in any way without the prior, written consent of Auber Instruments. Auber Instruments retains the exclusive rights to all information included in this
document.
Supplemental
Installation
Guide
for
Silvia
E
KIT
‐
RSRTDNb
(April
2016)
This
is
a
supplemental
guide
for
Rancilio
Silvia
E,
released
on
the
winter
of
2015
for
European
market.
Since
the
changes
of
Silvia
E
are
very
limited
from
Silvia
V4,
this
guide
only
cover
the
installation
steps
that
need
to
be
adjusted
due
to
these
changes.
The
only
difference
is
that
the
tapping
of
power
is
different.
The
main
power
switch
of
the
Silvia
E
has
changed
from
the
original
mechanical
ON/OFF
switch
to
a
push
button
reset
switch.
Therefore,
we
have
to
tap
the
power
from
the
brew
switch.
User
should
still
use
“KIT
‐
RSRTDN
Installation
guide
V2.2”
as
the
main
installation
guide.
1.
Tapping
the
Power
to
the
Controller
Replace
the
original
brew
thermostat
with
the
RTDStat
(pointed
by
the
blue
arrow
in
Figure
1).
Then
we
will
tap
two
cables
on
the
brew
switch
(pointed
by
green
arrows
in
Figure
1)
to
supply
power
to
the
controller.
The
green
arrows
point
to
a
red
and
a
black
cable
connected
to
the
lower
two
blades
on
the
brew
switch.
Figure
1.
Cables
need
to
be
tapped
are
pointed
by
green
arrows.
First,
remove
all
four
cables
on
the
brew
switch.
Connect
the
two
black
cables
with
piggyback
connectors
to
the
red
and
black
cable
removed
from
the
brew
switch.