Section 6: Interlock 

 

Interlocks serve to keep landing doors and gates closed when the lift is not at that landing.  

 

To install the interlock first locate the interlock & bracket on the door jamb as shown in view 
#2.  With the door closed  position near the top of the door jamb with the actuator tab & 
bracket inserted in the lock to determine the approximate position of lock and tab.  Secure the 
interlock bracket to the jamb and the tab bracket to the door using the wood screws provided. 
Note that the interlock and actuator tab mounting brackets are slotted allowing for full three 
axis adjustment. 

 

Once the interlock and the interlock tab have been mounted, wire the interlock into the lift as 
per the provided electrical schematics and wire diagrams using protective conduit as per the 
applicable electrical codes. 

 

 

Содержание Trus-T-Lift

Страница 1: ...0 TRUS T LIFT SUPPLEMENTAL MANUAL 2 LANDING DEVICES ...

Страница 2: ...RAM Elevators Lifts 1 800 563 4382 1 ...

Страница 3: ...nts Section 1 Introduction 1 Section 2 Safety Information 1 2 1 Symbols and Definitions 1 2 2 Additional Symbols 1 2 3 Safety Notes 2 Section 3 Upper Landing Gate 3 Section 4 Landing Door 5 Section 5 Remote Call Station 5 Section 6 Interlock 6 ...

Страница 4: ...hat may present special risks or consideration DANGER Danger messages indicate an imminently hazardous situation which if not avoided could result in serious injury or even death Caution Caution messages indicate a potentially hazardous situation which if not avoided could result in serious injury death or damage to equipment Note Note messages provide information such as reminders general informa...

Страница 5: ...to change the design of the product without written authorization by RAM Do not use an improper voltage source or a power source that provides poor quality power This may present a significant FIRE HAZARD and or permanent damage to the equipment Do not override any of the safety devices provided with the lift Doing so will likely lead to serious injury or even death Ensure that there is nothing ob...

Страница 6: ...RAM Elevators Lifts 1 800 563 4382 3 Section 3 Upper Landing Gate A Upper Landing Gate Frame B Spring Hinge C 4 x4 Angle D Interlock Bracket E Door Panel A B C D E ...

Страница 7: ...od for installing an upper landing gate just the recommended procedure from RAM 1 Mount the gate to your landing using one of two ways a Drill through the 4 x4 angle on the bottom of the door frame and use screws or lag bolts as shown in the diagram on the right or b Use a Polyurethane Adhesive to mount the threshold to the upper landing 2 Mount the Upper Gate Posts to the existing structure in on...

Страница 8: ...ding door DANGER Ensure that the lift has been disconnected from power before installing the following components Not doing so can damage the unit and lead to injury and or death Section 5 Remote Call Station A Trus T Lift Remote Call Station can be used to call the carriage to the landing or also send the carriage to an alternate landing when using a remote call send Each can be ordered with a op...

Страница 9: ...tor tab bracket inserted in the lock to determine the approximate position of lock and tab Secure the interlock bracket to the jamb and the tab bracket to the door using the wood screws provided Note that the interlock and actuator tab mounting brackets are slotted allowing for full three axis adjustment Once the interlock and the interlock tab have been mounted wire the interlock into the lift as...

Отзывы: