RAM Ele Lifts 

1-800-563-4382

 

DANGER

 

Ensure that before carrying out the next step, the lift has been disconnected from power. 
Not doing so can damage the unit, and lead to injury and/or death. 

 

3)

 

Wire the gate’s interlock into the tower as per the provided electrical schematics and 
wiring diagrams, using protective electrical conduit as per the applicable electrical codes. 
 

 

Section 4: Landing Door 

 

The installation of a Landing Door is very similar to the installation of a gate, just taller. Follow 
the previous procedure to install a landing door, taking into consideration the greater height of 
a landing door. 

 

DANGER

 

Ensure that the lift has been disconnected from power before installing the following 
components. Not doing so can damage the unit, and lead to injury and/or death. 

 

Section 5: Remote Call Station 

 

A Trus-T-Lift Remote Call Station can be used to call the carriage 
to the landing, or also send the carriage to an alternate landing 
when using a remote call/send. Each can be ordered with a 
optional key switch to control use.

 

 

 

 

 

To install a call station, simply mount it in a suitable location, and 
wire it into the lift’s top junction box as per the provided 
electrical schematics and wiring diagrams, using protective 
conduit as per the applicable electrical code requirements. 

 

 

Note

 

If you have a call station with

 

a key switch, the lift 

will 

not operate unless the key is in the on position 

(horizontal). 

Содержание Trus-T-Lift

Страница 1: ...0 TRUS T LIFT SUPPLEMENTAL MANUAL 2 LANDING DEVICES ...

Страница 2: ...RAM Elevators Lifts 1 800 563 4382 1 ...

Страница 3: ...nts Section 1 Introduction 1 Section 2 Safety Information 1 2 1 Symbols and Definitions 1 2 2 Additional Symbols 1 2 3 Safety Notes 2 Section 3 Upper Landing Gate 3 Section 4 Landing Door 5 Section 5 Remote Call Station 5 Section 6 Interlock 6 ...

Страница 4: ...hat may present special risks or consideration DANGER Danger messages indicate an imminently hazardous situation which if not avoided could result in serious injury or even death Caution Caution messages indicate a potentially hazardous situation which if not avoided could result in serious injury death or damage to equipment Note Note messages provide information such as reminders general informa...

Страница 5: ...to change the design of the product without written authorization by RAM Do not use an improper voltage source or a power source that provides poor quality power This may present a significant FIRE HAZARD and or permanent damage to the equipment Do not override any of the safety devices provided with the lift Doing so will likely lead to serious injury or even death Ensure that there is nothing ob...

Страница 6: ...RAM Elevators Lifts 1 800 563 4382 3 Section 3 Upper Landing Gate A Upper Landing Gate Frame B Spring Hinge C 4 x4 Angle D Interlock Bracket E Door Panel A B C D E ...

Страница 7: ...od for installing an upper landing gate just the recommended procedure from RAM 1 Mount the gate to your landing using one of two ways a Drill through the 4 x4 angle on the bottom of the door frame and use screws or lag bolts as shown in the diagram on the right or b Use a Polyurethane Adhesive to mount the threshold to the upper landing 2 Mount the Upper Gate Posts to the existing structure in on...

Страница 8: ...ding door DANGER Ensure that the lift has been disconnected from power before installing the following components Not doing so can damage the unit and lead to injury and or death Section 5 Remote Call Station A Trus T Lift Remote Call Station can be used to call the carriage to the landing or also send the carriage to an alternate landing when using a remote call send Each can be ordered with a op...

Страница 9: ...tor tab bracket inserted in the lock to determine the approximate position of lock and tab Secure the interlock bracket to the jamb and the tab bracket to the door using the wood screws provided Note that the interlock and actuator tab mounting brackets are slotted allowing for full three axis adjustment Once the interlock and the interlock tab have been mounted wire the interlock into the lift as...