MTR 221 ACS - MTR 221 ACS DHHS
MANUALE ISTRUZIONI / INSTRUCTION MANUAL
A
DJUSTMENTS
106
Model R 221 ACS - R 221 ACS DHHS
MTR 221
ACS
-
MTR 2
21
AC
S DHH
S - Adjustments
• Tilt the base until the laser
beam falls over the
perpendicular bisector line on
the anti-dust panel, see
Fig.
Laser Alignment.
• Tighten the two
B
screws.
M
OTOR
A
DJUSTMENT
• Disconnect supply.
• Remove the cover, see Chapter -
C
OVER
R
EMOVAL
.
• Loosen the 2 screws
C
on the motor
support, see
Fig. Motor Adjust-
ment.
• The plastic gears have a slightly oval
shape. Find the critical point and
adjust play on this point.
• Tighten the screws
C
.
• Remount the cover.
Photocell Adjustment
Remove the cover, see Chapter -
C
OVER
R
EMOVAL
.
Loosen the 2 screws
D
of the photocell
to adjust it, see
Fig. Photocell Adjustment.
Move the photocell until a return signal of photocell cut-off is received (related LED lights up on
PC board).
Once the photocell is adjusted tighten the screws
D.
Remount the cover.