Raisecom ISCOM2109F Скачать руководство пользователя страница 1

         

 

 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

www.raisecom.com 

 
 
 

ISCOM2109F Hardware Installation 
User Manual 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Содержание ISCOM2109F

Страница 1: ...www raisecom com ISCOM2109F Hardware Installation User Manual ...

Страница 2: ...age without the prior written consent of Raisecom Technology Co Ltd The information contained in this document is subject to change without notice Copyright Notices Copyright 2007 Raisecom All rights reserved No part of this publication may be excerpted reproduced translated or utilized in any form or by any means electronic or mechanical including photocopying and microfilm without permission in ...

Страница 3: ...6 10 82883056 World Wide Web You can access the most current Raisecom product information on the World Wide Web at the following URL http www raisecom com Feedback Comments and questions about how the ISCOM2109F device works are welcomed Please review the FAQ in the related manual and if your question is not covered send email by using the following web page http www raisecom com en xcontactus con...

Страница 4: ...er 4 Chapter 3 Device Appearance 5 3 1 Device front panel description 5 3 2 Device rear panel description 6 Chapter 4 Installation and Application 7 4 1 Before the installation 7 4 2 Device installation 9 4 2 1 Environment requirement 9 4 2 2 Install the device on to a rack 9 4 2 3 Grounding 9 4 3 The connection of the switch 9 4 3 1 Connect to console 9 4 3 2 Connect to Ethernet 11 4 3 3 Connect ...

Страница 5: ...at the fiber optic cable is intact and is connected to the transmitter Do not attempt to adjust the laser drive current Do not use broken or unterminated fiber optic cables connectors or look straight at the laser beam The use of optical devices with the equipment will increase eye hazard Use of controls adjustments or performing procedures other than those specified herein may result in hazardous...

Страница 6: ...nstalled in a restricted access area i e an area where access is authorized only to qualified service and maintenance personnel Make sure that the DC supply is electrically isolated from any AC source and that the installation complies with the local codes Before connecting the DC supply wires ensure that power is removed from the DC circuit Locate the circuit breaker of the panel board that servi...

Страница 7: ...running at 100Mbps 100BASE X A term in IEEE 802 3 for Gigabit Ethernet over fiber based on 8B 10B coding and running at 1000Mbps Auto Negotiation The auto negotiation procedure is the port at one site adapts its bit rate and duplex mode to the highest level it and the opposite site device both support according to the bit rate and duplex mode adopted by the remote site device that is the connected...

Страница 8: ...configured to interface for 1000BASE TX 1000BASE FX or 100BASE FX cards The power consumption of the system is less than 20W 2 2 Device dimension The dimension of ISCOM2109F switch s main structure is 1U Height x 440mm Width x 180mm Depth The device weighs about 6kg and can be either fixed into a 19 inch cabinet or placed on a table 2 3 Device operating environment Environment temperature 10 C 45 ...

Страница 9: ...tors SYS and PWR Indicator Color Status Description ON The system is initializing after electrifying Flickering The system is operating in order SYS Green Other Status Software fault ON The system is electrified PWR Green OFF The system is not electrified 8 100BASE FX Ethernet interfaces and their corresponding status indicators There are 2 indicators for an interface LNK and ACT Indicator Color S...

Страница 10: ...ce rear panel is shown in the figure below 2 1 In the figure shown above The place where the socket for 220V AC power supply locates The place where the switch for 220V AC power supply locates 2 The location for the socket for 48V DC power supply on the device rear panel is shown in the figure below In the figure shown above The place where the switch for 48V DC power supply locates The place wher...

Страница 11: ...0M electrical interface The number for the electrical interface is 9 The interface is in support of AUTO MDI MDIX when the auto negotiation function is enabled and 10 100 1000M self adaptation The panel of SC200 GE T is shown in the figure below 10M 100M LNK ACT 1000M 3 3 1 2 1 10 100 1000M Ethernet electrical interface The status indicators for the Ethernet electrical interface Indicator Color St...

Страница 12: ...OFF When the port is in Link Up status it indicates that the port is not connecting to the Ethernet at the rate of 1000Mbps Fit screw used to fix the card on to the switch Sub card SC200 GE S1 Sub card SC200 GE S1 provides 1 1000M optical interface The number of the interface is 9 The optical interface is in support of transmission of 20km The panel of SC200 GE S1 is shown in the figure below LNK ...

Страница 13: ...r flow unblocked Please make sure the outlets are not blocked 4 2 2 Install the device on to a rack To set the switch firmly into a rack please fix the installation tray to the switch using the four screws come with the device and fasten the installation handle on to the rack 4 2 3 Grounding To ensure the safety of the device and the operator please make sure that the grounding terminal is well co...

Страница 14: ...N C No connection b PC serial port signal definition The pin number and pin function definition of 9 pin serial port connector is shown in the figure and table below Pin Number Function Type Pin Number Function Type 1 CD 6 DSR 2 RxD IN 7 RTS 3 TxD OUT 8 CTS 4 DTR 9 RI 5 GND Ground c CONSOLE interface connecting pattern and parameter setup The connecting of ISCOM2109F CONSOLE interface and PC seria...

Страница 15: ...the rear panel of the switch with 48V DC power supply using the provided power supply cable Note that there is a switch for the 48V DC power supply on ISCOM2109F After connecting ISCOM2109F to the power supply please turn on the switch to begin the electrifying of the device 4 4 Electrify the switch After installing the switch following the steps above connect the switch to power supply using the ...

Страница 16: ... Manual 12 terminal software is correctly configured the user management interface on which users can operate over the switch will appear on the PC For details please refer to the corresponding software configuration manual ...

Страница 17: ...ow humidify may lead to fire alarm In a word the switch must be placed in proper surroundings The power supply of the device should be well earthed to let out the static electricity Please keep some space from other powered devices when installing the switch The cable arrangement of the switch should have all cables be placed across the live wire Long distance close parallel of the cables and the ...

Страница 18: ...ress 2nd Floor South Building of Rainbow Plaza No 11 Shangdi Information Road Haidian District Beijing Postcode 100085 Tel 86 10 82883305 Fax 86 10 82883056 Email export raisecom com http www raisecom com ...

Отзывы: