Replace Y Shaft Coupler
Manual Pro2 Series - 060 Replace Y Shaft Coupler-V1.0
Tools:
①
2.5mm wrench
②
2mm wrench
③
Philips head screw driver
1. Unload filament
•
In the ‘Utilities’ tab, verify that the temperature is set for your material. (215
℃
for
Raise3D PLA)
•
Use the arrows to adjust the temperature if required. Press the ‘unload’ button to
begin.
•
The printer will begin to heat up to the designated temperature. Once the
temperature is reached the Unload button will become available.
•
Press Unload to withdraw the filament.
Содержание Pro2 Series
Страница 4: ...7 Loosen the screws in the Shaft Coupler at rear right corner with 1 5mm hex wrench ...
Страница 9: ...14 Slide the coupler forward and back to verify the motor shaft and rod are aligned ...
Страница 11: ...17 Tighten the four screws on Y Coupler 18 Zip tie the harness back to top cover 19 Connect the Air Filter ...
Страница 12: ...20 Re install the top cover 21 Re install the back cover Manual Pro2 Series 060 Replace Y Shaft Coupler V1 0 ...