background image

Manual Pro2 Series - Replacing 

Thermocouple and Heating Rod-V1.0 

1. Move the build plate to home position. Select 10mm as Move Steps, and drop the build

plate 250mm. 

2. Set both extruders to unload temperature (recommend to set the target temperature to 5-

10C higher than its normal printing temperature). Unload the filament, and remove the 

filament and filament guide tubes from the extruder. 

3. At home page, set the nozzle temperature to be 0C and wait for the nozzles to reach

ambient temperature. 

Version 1.0 

Date:29/08/2018

www.raise3d.com

Содержание Pro2 Series

Страница 1: ...oth extruders to unload temperature recommend to set the target temperature to 5 10C higher than its normal printing temperature Unload the filament and remove the filament and filament guide tubes fr...

Страница 2: ...4 Remove the two set screws from model cooling fan with 2 5mm hex wrench Loosen the 4 set screws inside the heating block Version 1 0 Date 29 08 2018 2 www raise3d com...

Страница 3: ...with 2 5mm hex wrench Remove the Hot end from the print head Take the Heating Rod and Thermocouple out from the Hot end 6 Remove the two black screws from the back casing and take the casing off Vers...

Страница 4: ...7 Cut the zip tie cables 8 Remove the two hex screws from Extruder Board Version 1 0 Date 29 08 2018 4 www raise3d com...

Страница 5: ...9 Remove the Heating Rod or Thermocoupler from the terminals marked below by loosening the screws with flat head screwdriver on Extruder Board Version 1 0 Date 29 08 2018 5 www raise3d com...

Страница 6: ...but do not cut them Insert the cables of the Thermocoupler into the terminal and tighten the screws Ensure there are no exposed wires touching on another as it may cause harm to the printer Pay atten...

Страница 7: ...3 10 Insert the Heating Rod all the way into the lower hole of the Hot end until it reaches the other end Tighten the two set screws 11 Insert the Thermocoupler all the way into the upper hole of the...

Страница 8: ...12 Insert the Hot end back onto the collet and push up until the upper surface of the fin touches the collar Tighten the hex screw Install the fan back Version 1 0 Date 29 08 2018 8 www raise3d com...

Страница 9: ...h the casing back to cover the cables After reinstalling the hot ends z offset will need to be recalibrated please use the z offset guide Manual Pro2 Series Replacing Thermocouple and Heating Rod V1 0...