background image

ENGLISH                            RAIS - manual for Q-BIC  & Q-BIC insert                                                        

1

U S E R   M A N U A L

       

RAIS Q-BIC

                    &

     RAIS Q-BIC INSERT

Содержание Q-BIC INSERT

Страница 1: ...ENGLISH RAIS manual for Q BIC Q BIC insert 1 U S E R M A N U A L RAIS Q BIC RAIS Q BIC INSERT...

Страница 2: ...We cannot be held responsible for any misprints...

Страница 3: ...L 20 22 GENERAL INSTALLATION 21 RIGHT ANGLE SECURE BASE 21 CORNER INSTALLATION 45 22 360 SWIVEL BASE 22 FOR THE INSTALLER 23 OPERATING INSTRUCTIONS 24 FUEL 24 DRYING AND STORAGE 25 REGULATION OF COMBU...

Страница 4: ...is important that you read the manual thoroughly before installing and using it In the case of warranty coverage and for general queries regarding your wood burning stove it is important that you kno...

Страница 5: ...404 404 1270 426 418 850 Combustion chamber s width depth height mm 288 288 500 288 288 500 288 288 500 Recommended amount of wood when fuelling kg Distributed on 2 3 logs of wood of approx 25 cm 1 6...

Страница 6: ...hroughout the entire room The cold air is sucked in at the base of the stove up through the convection channel which runs along the stove s combustion chamber The heated air pours out at the top of th...

Страница 7: ...e The installation of this heating appliance is governed by the Health and Safety at Work Act 1974 It is the responsibility of the installer to ensure that all requirements of this Act are met during...

Страница 8: ...egulations Approved Document J Any existing chimney must be clear of obstruction and have been swept clean immediately before installation of the stove If the stove is fitted in place of an open fire...

Страница 9: ...ssible soot door or doors must be provided for sweeping the chimney and connecting fluepipe You should also familiarise yourself with the draught conditions for chimneys with 2 flues The flue outlet s...

Страница 10: ...9900 Frederikshavn Danmark 043 152 200 mm 100 mm 0 20 253 C 4 5 kW 75 Anordningen er egnet til r ggassamleledning tr 07 Q BIC INDSATS Manufacturer s Plate for Q BIC insert Installation It is prohibite...

Страница 11: ...ENGLISH RAIS manual for Q BIC Q BIC insert 11...

Страница 12: ...and the screw in lower left corner both door side do not onscrew entirely now it s possible to remove the insert from the cassette Prefaration of cassette Disassemble the two screws keeping the stiffe...

Страница 13: ...panelled wall all 3 legs are used and for brick wall only the back leg is used Assembly the topplate with the following self drilling screws By a brick wall The outermost part of the upper covering is...

Страница 14: ...manual for Q BIC Q BIC insert 14 Fitting hole for brick wall Fitting holes for angle brace for panelled wall ATTENTION Important that the cassette is posotion in 90 angel and levelled both horizontal...

Страница 15: ...se plate and place it as shown in the picture on the left NB Basic settings on the adjusting bolts are approx 32 5 mm between the bottom of the stove s base and the base plate on the internal box Plea...

Страница 16: ...16 Push the insert until the front is in level with the wall Afterwards push the insert from the other side until it is in level with the other wall The screws in upper right corner and lover left co...

Страница 17: ...ENGLISH RAIS manual for Q BIC Q BIC insert 17...

Страница 18: ...17 516 524 100 100 198 197 743 Min 734 Min Min 200 Min 200 OBS Hullerne i bunden m ikke d kkes til Q BIC insert Mounting distance for panelled wall combustible material insulation ability such as Aqua...

Страница 19: ...ialt 500 cm 425 417 434 Min 426 Min 643 Min 617 Min 10 15 15 232 233 300 300 Gulvplade 643 Min 617 Min Anbefalet afstand min Afstand til loft min 500 Mounting distance for brick wall firewall Total m...

Страница 20: ...ed by wall brackets or a ceiling support plate The weight of the stove is indicated in the brochure The stove should always be installed on a non combustible hearth of a size and construction that is...

Страница 21: ...Q BIC insert 21 Normal set up right angle secure base A Distance to furniture 750 mm Distance to flammable materials B in front floor 300 mm C to the side floor 150 mm D to the rear floor 350 mm E to...

Страница 22: ...A Distance to furniture 750 mm Distance to flammable materials B in front floor 300 mm C to the side floor 150 mm D to the rear wall 200 mm E to the side of the wall 500 mm 360 swivel base A Distance...

Страница 23: ...nce connections to the chimney Ensure that the appliance and chimney flue are functioning correctly before finally handing over to the user If necessary read the later parts of this manual for guidanc...

Страница 24: ...ood with a synthetic surface painted refuse wood chipboard plywood domestic waste paper bri quettes and pit coal as this will produce malodorous smoke which could be poisonous When firing with the abo...

Страница 25: ...is the air which is added in the gas combustion zone i e air which contrib utes to the combustion of the pyrolysis gasses preheated air which is used for the cleaner glass system and combustion This a...

Страница 26: ...the marking is This position gives full secondary air During normal stoking the lever is set between posi tion 1 and 2 When the flames are clear and yellow the damper is set correctly i e resulting i...

Страница 27: ...e resulting in a slow optimal burning Position 3 Press the handle in and push it to the left until stop The air damper is completely open and gives full primary and secondary air The position is for t...

Страница 28: ...used by the large temperature differences which the material is subjected to Never use any type of liquid fuel for kindling or maintaining the fire You could be at risk of explosion The stove gets ver...

Страница 29: ...per between the upper baffle plate and the chimney set the paper on fire and wait until you hear a rumbling noise in the chimney This means that there definitely is a draught in the chimney and you av...

Страница 30: ...bed of glowing embers add 2 3 pieces of wood Leave the door ajar until the fire has caught on properly close the door Damper see adjustment of air damper After approx 5 min or when the flames are cle...

Страница 31: ...ecome clean As an alternative you can use glass polish which you can buy from you RAIS distributor Clean the exterior with a dry sponge Cleaning the combustion chamber Scrape shovel the ash out and st...

Страница 32: ...e in the next picture Cleaning of the flue ways The baffle is pulled towards the front and is tipped down towards the firebox Note that the skamol on the sides are now loose The smoke connector is pla...

Страница 33: ...seal chimney draught too large 22 Pa draught control regulator should be installed A stove burning too weakly could be caused by too little firewood too little air supply for room ventilation unclean...

Страница 34: ...1090 95 Door 6 1 7060905sv Handle for air control 7 1 7061301 Smoke connector 8 1 7062200 Set of skamol stones 9 1 7060590 95 Fixed socket 10 1 7051590 95 Swivel base 11 1 7055500 Seal set Accessories...

Страница 35: ...ENGLISH RAIS manual for Q BIC Q BIC insert 35...

Страница 36: ...706060290 95 Top plate 2 1 706010490 95 Steel back panel 3 1 706010590 95 Fixed window 4 1 706010190 95 Steel side panel 5 1 7061090 95 Door 6 1 7060905sv Handle for air control 7 1 7061301 Smoke con...

Страница 37: ...ENGLISH RAIS manual for Q BIC Q BIC insert 37...

Страница 38: ...1 1 707170190 95 Complete front 2 1 706010590 95 Fixed window 3 1 7061090 95 Door 4 1 7060905sv Handle for air control 5 1 7061301 Smoke connector 6 1 7062200 Set of skamol stones 7 1 7071301SV Compl...

Страница 39: ...ENGLISH RAIS manual for Q BIC Q BIC insert 39 6 2 10 4 3 9 1 7 5 8...

Страница 40: ...RAIS A S Industrivej 20 DK 9900 Frederikshavn www rais dk...

Отзывы: