background image

For tech support and protocols call

  

1-877-272-6747

 

 

www.treecarescience.com

  

  

[email protected]

Patent Pending

The Q-gun is designed to allow tree injection treatments to be performed quickly, safely, and accurately. 

Be certain to read ALL instructions before use. Refer to the appropriate product guide and product label 

for dosage and mixing instructions. 

MANUAL

Overview • Use • Care & Storage • Troubleshooting  • Repair

Содержание Q-gun

Страница 1: ...Pending The Q gun is designed to allow tree injection treatments to be performed quickly safely and accurately Be certain to read ALL instructions before use Refer to the appropriate product guide an...

Страница 2: ...ING PHASE 3 INJECTING PHASE 4 PURGING PHASE 5 CLEANING GENERAL CARE STORAGE APPROVED PRODUCTS LIST TROUBLESHOOTING MAINTENANCE REPAIR TAKING APART PUTTING TOGETHER THE Q GUN FIELD REPAIR INSTRUCTIONS...

Страница 3: ...Q gun Field Repair Kit Recommended Dosing chamber 0 20ml Plunger BOTTLE CAP ASSEMBLY top view 1 Included You Will Need Push to connect Handle Handle Tension Dial Push to connect Inside Dial Outside D...

Страница 4: ...DBH set the dosing chamber to 4 ml To Set The Injection Dose Use the silver dials at the base of the handle Squeeze the handle and loosen both dials to adjust the dosing chamber Move the handle to the...

Страница 5: ...e the handle to draw product into the gun chamber Repeat until the lines are primed TIP Hold the gun with the tip pointing upward to eliminate air bubbles in the dosing chamber while priming Determine...

Страница 6: ...ace so the handle may be released without refilling the chamber Remove the injection tee with another slight clockwise turn while pulling it out Repeat steps 2 4 for each injection site Space holes ev...

Страница 7: ...ohol cleaning solution To make a cleaning solution mix ONE 1 part 70 isopropyl alcohol to TWO 2 parts water NOTE For 90 isopropyl alcohol mix ONE 1 part alcohol to THREE 3 parts water Repeat Phase II...

Страница 8: ...of the device as needed Keep check valve cores and O rings clean and lubricated Store your Q gun in a dry area free from dust and particulate matter Store above 32 F 0 C and below 100 F 38 C GENERAL...

Страница 9: ...n Apply silicone grease to valve cores Replace check valves if problem persists Fluid leaking from cylinder Blue O rings are worn out Performance may be improved temporarily with lubrication NJ Philli...

Страница 10: ...c Maintenance Checklist DAILY after use Purge product Run isopropyl alcohol cleaning solution through system Check tubing and injection tip for obstructions AFTER HEAVY USE OR AS NEEDED Run fresh clea...

Страница 11: ...um capacity b Squeeze handle and twist plunger cap to release plunger cap c Release handle 2 To remove check valve cores a Unscrew front cover and remove push to connect fitting b Unscrew rear push to...

Страница 12: ...or chemical residue build up deep scoring and kinks NOTE Push to connect fittings are designed to score the tubing to hold it firmly in place Over time the scoring becomes deeper and can cause leaking...

Страница 13: ...the metal shim and the rubber grommet last Replace the brass valve plug and tighten until hand tight DO NOT over tighten 5 V REPLACING CHECK VALVES 1 Disconnect tubing from the gun Unscrew the front t...

Страница 14: ...e to relax plunger completely 2 Twist plunger cap counter clockwise to release piston from cylinder 3 For tech support and protocols call 877 272 6747 12 FIELD REPAIR INSTRUCTIONS 3 Check valves 4 4 R...

Страница 15: ...For tech support and protocols call 1 877 272 6747 www treecarescience com info treecarescience com...

Страница 16: ...isfaction in every way service performance quality and value If you are ever dissatisfied in any way please contact us so that we can address whatever concern you have Our goal is your complete satisf...

Отзывы: