Warning
This manual describes the Modbus server (slave controller). See Section 6 for a
description of the Modbus client features.
1. Overview
RB's Modbus TCP server (slave controller) is fixed at port number 502. The IP address
changes depending on the network settings through the UI. (The initial IP address is
10.0.2.7.)
RB's Modbus server allows the connection of multiple clients and executes the following
operation commands.
Function Code
Function Name
Bit
Address
2
Read Discrete Inputs
1
Read Coils
5
Write Single Coil
15
Write Multiple Coils
16-bit
(Word)
Address
4
Read Input Registers
3
Read Multiple Holding Registers
6
Write Single Holding Register
16
Write Multiple Holding Registers
2. Exception Code
The following error message is returned when accessing the wrong address, incorrect range
of values, or invalid command sent.
Exception Code
Exception Name
1
Illegal Function
2
Illegal Data Address
3
Illegal Value
Содержание RB Series
Страница 1: ...RAINBOw English RB SERIES USER MANUAL V 3 9 1 Update 2021 09...
Страница 2: ...RAINBOW ROBOTICS RB SERIES _ USER MANUAL RAINBOW ROBOTICS Inc All rights reserved 2...
Страница 80: ...RAINBOW ROBOTICS RB SERIES _ USER MANUAL RAINBOW ROBOTICS Inc All rights reserved 80 Program only Mode...
Страница 195: ...RAINBOW ROBOTICS RB SERIES _ USER MANUAL RAINBOW ROBOTICS Inc All rights reserved 195...
Страница 206: ...RAINBOW ROBOTICS RB SERIES _ USER MANUAL RAINBOW ROBOTICS Inc All rights reserved 206...
Страница 265: ...RAINBOW ROBOTICS RB SERIES _ USER MANUAL RAINBOW ROBOTICS Inc All rights reserved 265...