background image

START
PROG

END

SESSIO N

SET

STA#

1 /A

2 /B

3 /C

4 /D

5 /E

6 /F

7 /G

8 /H

9 /J

CLEAR

O /TEST

STO P

START
PROG

END

SESSIO N

SET

STA#

1 /A

2 /B

3 /C

4 /D

5 /E

6 /F

7 /G

8 /H

9 /J

CLEAR

O /TEST

STO P

SET

TIM E

SET

PROG

O N

ADV

© 2000 Rain Bird Sprinkler Mfg. Corp. 3/00

Contents

DESCRIPTION ............................................................. 2
INSTALLING THE BATTERY ......................................... 4
BEFORE REGISTERING THE ACCESS CODE ............... 5
REGISTERING AN ACCESS CODE IN A RECEIVER ...... 6
TESTING THE SYSTEM ............................................... 7
USING THE RMX-1T TRANSMITTER ............................ 8
REMOTE SEQUENCE ................................................ 10
CONTROLLER PROGRAM ......................................... 12
SPECIAL COMMANDS (RMX-1R only) ..................... 13
OTHER FUNCTIONS .................................................. 17

RMX-1T Keypad Transmitter

(with STX™ Security)

RMX-1Tsande.p65

3/7/00, 10:13 AM

1

Содержание RMX-1T

Страница 1: ...DV 2000 Rain Bird Sprinkler Mfg Corp 3 00 Contents DESCRIPTION 2 INSTALLING THE BATTERY 4 BEFORE REGISTERING THE ACCESS CODE 5 REGISTERING AN ACCESS CODE IN A RECEIVER 6 TESTING THE SYSTEM 7 USING THE...

Страница 2: ...ds a radio frequency RF signal to the receiver which then sends commands to a Rain Bird remote ready irrigation controller The transmitter can operate at a range of up to 700 feet 214 m Registering Ac...

Страница 3: ...xample In this illustration transmitter has an access code registered in receiver A while transmitter has access codes registered in receivers A B and C Buttons and Indicators The keypad contains func...

Страница 4: ...rnewtransmitters removethe seal or wrap from the 9 volt battery included If you are replacing the battery remove the old battery and discard it appropriately Attach the new battery to the battery conn...

Страница 5: ...for each receiver Should you lose your code you can register a new one in the receiver s memory For more information see CheckReceiverMemory Check Receiver Memory There is a limit to the number of acc...

Страница 6: ...ESS CODE IN A RECEIVER Press the CLEAR button Press the END SESSION button Enter the access code and press the ON ADV button Press the receiver s Channel 1 button The receiver s indicator LED will lig...

Страница 7: ...n Press the END SESSION button Enter the access code for the receiver and press the ON ADV button Release the ON ADV button and pause a moment Hold down the ON ADV button for a count of 1 The LED on t...

Страница 8: ...have run time scheduled in any program During a remote sequence each station runs for 10 minutes This function can be useful for System checkout after installation Winterizingasystem Conducting a walk...

Страница 9: ...ction Remote Control Receiver and a remote ready ESP LX controller Special commands include Start an individual station to run for up to 99 minutes 30 minute default Change a station s run time in a p...

Страница 10: ...ogrammed run time in any program will operate automatically for a maximum of 10 minutes The remote sequence always begins with the lowest numbered station The rest of the stations will operate in nume...

Страница 11: ...Remote Sequence Press the ON ADV button and hold it down until all watering stops about 4 seconds While you are holding the button down the controller will temporarily advance to the next station The...

Страница 12: ...button The next station in the program s sequence will begin operating and the previous station will end The controller will display the station number currently operating along with its run time in...

Страница 13: ...ble only with the RMX 1R Multi Function Receiver and a remote ready ESP LX controller Start Station This command will start any station even if it is not scheduled in any program and run it for 30 min...

Страница 14: ...n and run it for a specific amount of time up to 99 minutes This is a one time command that will not affect the controller s programming Enter the run time in minutes up to 99 and press the SET TIME b...

Страница 15: ...controller for the station and program you select The command will not start the station NOTE Set the ESP LX controller dial to AUTO Enter the run time in minutes up to 99 and press the SET TIME butt...

Страница 16: ...e program letter and press the START PROG button Example To start program B press the buttons as shown in the Start Program box at right To stop the program at any time press the STOP button Start Tes...

Страница 17: ...e while entering a command press the CLEAR button and start over NOTE Controllers will ignore commands that exceed their capacity For example an ESP 16LX will ignore a command to start Station 20 or t...

Страница 18: ...a second receiver you must clear the transmitter s memory Press the CLEAR and END SESSION buttons to clearthetransmitter smemory If the receiver is not responding to commands the problem could be in...

Страница 19: ...inutes with any command if the sensor is active To cancel the sensor override at any time press the END SESSION button This device complies with FCC Part 15 and IC Rules and Regulations Operation is s...

Страница 20: ...ion 145 North Grand Avenue Glendora California 91740 U S A 626 963 9311 2000 Rain Bird Sprinkler Mfg Corp Registered trademark of Rain Bird Sprinkler Mfg Corp Technical Services 800 247 3782 http www...