Basic Setup
Clearing a Latched Relay
To clear a relay that latches after a trigger:
1� Navigate to the main menu�
2� Press UP/DOWN to scroll to
UNLATCH R1
or
UNLATCH R2
, then press ENTER�
Passcode Setup
Enabling a Passcode
PT5002 units are shipped without passcode protection enabled� Passcodes can be
optionally configured for
Setup
and
Reset
functions� To enable a passcode:
1� Navigate to
SETUP > PASSCODE SETUP
�
2� Press UP/DOWN to scroll to the passcode you want to enable, then
press ENTER�
Figure 16: Set passcode screen
3� Enter a numeric passcode from 4 to 8 digits in length, then press ENTER�
4� On the confirmation screen, press ENTER again to confirm the passcode�
OTE:
N
An asterisk ( * ) appears next to each passcode if it is enabled�
Figure 17: Asterisk indicates set passcode