13.1.3 Set FloZone Rates
Set Flow Rates
Next
Learn Flow
Set Station Rates
Set FloZone Rates
View Flow Rates
Clear Flow Rates
Set FloZone Rates
Done
FloZone
001
Max GPM
2000.0
Do not set rate
below 0000.0
MV(s) 1
FS (s) 1
1
Turn the controller dial to Flow Sensor
2
At the FLOW SENSOR screen, with “
Set Flow Rates
” selected, press
Next
.
3
At the Set Flow Rates screen, press the key to select Set FloZone Rates, then press
Next
.
4
The Set FloZone Rates information screen appears; press
Next
.
•
The LXME2 features one FloZone.
5
Press the right arrow key to navigate to the MAX GPM field.
6
Press the and keys to set the Max GPM for that FloZone. Press the and to
navigate between the number setting fields.
•
Press and HOLD keys to accelerate settings.
NOTICE
Maximum FloZone flow rates are used only by Flo-Manager®. FloWatch is unaffected by user-entered
FloZone flow rates.
7
After Flo-Manager® is enabled and station and/or FloZone flow rates are entered, Flo-
Manager® works automatically in the background to run stations based on available
hydraulic capacity.
•
Flo-Manager® can be used with or without flow sensing hardware. If flow sensors are not present it will rely
on manually entered information; if flow sensors are present it will rely on Learned Flow information, which
is typically more accurate.
13.1.4 View Flow Rates
Occasionally you may want to view user entered or learned flow rates and their source for a station
or FloZone.
•
View Flow Rates does not show actual live flow rates but the expected or learned flow rates by station or