manualshive.com logo in svg
background image

Auto Configure

Master Valves

Sensors

FloManager

FloWatch

Edit Configuration and Stations...

Direct Satelitte Tasks

Select One or More Sites...

Site Name

Out of Sync

Satellite Changes

Alarm

Satellites Off

Auto Contacts...

Add Site...

Synchronize

Edit Site...

Retrieve Logs...

Site Name

Description

Time Zone

Postal Code

(UTC-8:00) Pacific Time (US and Canada)

Site 01

OK

Cancel

Satellites

Program...

Dry Run...

Manual Operations...

Configure...

Add...

Auto Configure

Master Valves

Sensors

FloManager

FloWatch

Edit Configuration and Stations...

Direct Satelitte Tasks

Client Satellite

LXME

Client Satellite

Server Satellite

2

0 gal/min

1

1

Satellite Name:

Type:

Connection Type:

Server:

Network Address:

Description:

Dry Run Warning for Max Flow:

Max. Satellite Irrigation SimulStations:

Max. Satellite Non-Irrigation SimulStations:

PIN-Codes:

Weather Source:

Configuration Stations

OK

Cancel

Unprotected

Detect Modules automatically and update IQ

Upload Satelitte Configuration into IQ

Upload Satelitte Programming into IQ

Retrieve Learned Flow Data into IQ

OK

Cancel

Modules

Configuration

Programs

Learned Flow

1.  Choose Satellite

2.  Choose IQNet Type

LXD

Direct

LXME

Server

Choose the IQNet Server for this Client:

Server Satellite

LXMEF

LXM

Client

OK

Cancel

Auto Configure

Master Valves

Sensors

FloManager

FloWatch

Edit Configuration and Stations...

Direct Satelitte Tasks

Satellite 001

LXME

IP Connection

10.84.177.16

5005

0 gal/min

1

1

Satellite Name:

Type:

Connection Type:

Phone Number / IP Address

Port:

Description:

Dry Run Warning for Max Flow:

Max. Satellite Irrigation SimulStations:

Max. Satellite Non-Irrigation SimulStations:

PIN-Codes:

Weather Source:

Configuration Stations

OK

Cancel

Unprotected

Satellites

Program...

Dry Run...

Manual Operations...

Configure...

Add...

1.  Choose Satellite

2.  Choose IQNet Type

LXD

Direct

LXME

Server

LXMEF

LXM

Client

OK

Cancel

1

IQNet Server/Client Communication

•  Connection Module (CM) PE-Cable and/or Radio Secondary Communication

IQNet Server/Client 
Communication Overview

Allows a single Server Satellite with IQ pri-
mary communication connection (Cellu-
lar, Ethernet, etc.) to be shared with up to 
255 Client Satellites via Radio and/or Con-
nection Module (CM) PE-Cable secondary 
communication. 

a.  Utilizes lower cost IQNCCRS RS-232 

Cartridges for Client Satellites.

b.  Reduces yearly reoccurring  com-

munication costs for systems using 
Cellular communication.

c.  Provides Normally Closed Master 

Valve or Pump Start sharing be-
tween Server and Client Satellites.

d.  Provides Weather Sensor (not Flow 

Sensor) sharing between Server 
and Client Satellites.

Rain+Birdt

IQNCCRS RS-232 Network Communication Cartridge -
IQNet Server/Client Installation & IQ-Cloud Configuration

For Additional Information

See IQ-NCC Cartridge Installation 
and Operations Guide for IQ3G-
USA Cellular and IQNCCEN 
Ethernet Cartridge Installation 
and Configuration Instructions.

Go to www.RainBird.com/
for training, presentations, 
product literature and 
information for IQ-
Enterprise and IQ-Desktop.

IQ-Cloud Support

(800) 254-0692 
I

[email protected]

 

www.RainBird.com/IQ

Rain Bird Global Service Plan (GSP)

(866) 477-9778 
[email protected]

9

Go to www.rainbird.com/iq

New users: Select IQ-Cloud Sign-up.

Existing users: Select IQ-Cloud Login.

10

Select Add Site

13

Add Client Satellites

Choose ESP-LX Controller Type.

Select Client IQNet Type.

14

Configure Client Satellites

Select Edit Configuration and Stations.

Enter the unique IQNet Network Address (2 to 56) that you selected in the 
Setup Wizard for each Client Satellite.

15

Reverse Sync Data from each Satellite

Select Auto Configure.

Check All Options.

2018 Rain Bird Corporation

t

Registered trademark of Rain Bird Corporation
P/N: 690656-01  Rev. 6/18   D41261

3

Attach IQ Cables to Cartridges in Server and 
Client Satellites

Select the 
Server Satellite 
this Client is 
connected to.

12

Configure Server Satellite

Select Edit Configuration and Stations.

Select IP Connection Type, enter the IP Address and Port Number for IQ-Cloud 
to communicate to the Server Satellite.

11

Add Server Satellite

Choose ESP-LX Controller Type.

Select Server IQNet Type.

2

Install IQ-NCC Cartridges

4

Attach IQ Cables to Radio/CM Module

Attach Supplied Y-Cable to Radios or Straight-Cable to CM Modules

8

Check IQNet Satellite Communication Status from 
the Client Satellites

7

Test Satellite Communication from the 
Server Satellite

The Setup - Satellite Type 
screen is displayed. Use + 
or - to select Direct' press 
Next.

NOTE:

 The IQ Port status 

will allways show Disabled for 
Client Satellites.

g

Turn the controller dial to 
ETM/IQ Settings

5

Setup Wizard for Server Satellite

g

Turn the controller dial to 
ETM/IQ Settings

6

Setup Wizard for Client Satellite

g

Turn the controller dial to 
ETM/IQ Settings

The Setup - Satellite Type screen is 
displayed. Use + or - to select Client; 
press Next.

The Setup – Satellite Address screen 
is displayed. Use + or - to select a 
unique address from 002-256 for 
this satellite (press and HOLD but-
tons to accelerate settings); press 
Next.

The Setup – Satellite Radio 
Port screen is displayed. Use + 
or - to select a radio port op-
tion (No Radio Installed, Radio 
Installed); press Next.

The Setup – Satellite CM Port 
screen is displayed. Use + or - 
to select a CM Port option (No 
Module, Module Installed); 
press Next.

The Setup – CM Port 
Termination screen is dis-
played. Use + or - to select a 
CM Port Termination option 
(On or Off).

NOTE:

 CM Port 

termination is only 
required if this satellite is 
at the end of an IQNet PE 
Communication Cable path. 
If you are not sure, consult 
with the system designer. 

The IQ Settings main menu is 
displayed. Use the UP or DOWN 
arrows to select Setup Wizard; 
press Next.

The Setup - Satellite Type 
screen is displayed. Use + or - 
to select Server; press Next.

The Setup – Satellite Address 
screen is displayed. Server 
Satellites always have an ad-
dress of 001; press Next.

 

The Setup – Satellite IQ Port 
screen is displayed; press Next.

The Setup – Satellite Radio 
Port screen is displayed. Use + 
or - to select a radio port op-
tion (No Radio Installed, Radio 
Installed); press Next.

The Setup – Satellite CM Port 
screen is displayed. Use + or 
- to select a CM Port option 
(No Module Installed, Module 
Installed); press Next.

g

Turn the controller dial to 
ETM/IQ Settings

The IQ Settings main menu is dis-
played. Use the UP or DOWN ar-
rows to select Status; press Next.

The Satellite Status screen is 
displayed. Current status of IQ, 
Radio, and CM ports are shown. 
Press Signal to display 3G signal 
strength.

The Signal Strength is displayed.  
The signal strength between the 
satellite and the 3G Cellular net-
work is indicated on a scale of 
1-10.

The Satellite Status screen is dis-
played. Current status of IQ, Radio, 
and CM ports are shown. Press 
Ping to check the communication 
status with selected Clients.

The IQNet Ping screen is displayed. 
Use the + and - buttons to select 
any Client address. Press Ping to 
check the communication status.

The LCD will display Response-Yes 
if the ping is successful, or No for 
an unsuccessful ping. 

The IQ Settings main menu is dis-
played. Use the UP or DOWN arrows 
to select Setup Wizard; press Next.

The IQ Settings main menu is dis-
played. Use the UP or DOWN arrows 
to select Status; press Next.

Install IQ3G-USA Cellular or 
IQNCCEN Ethernet Cartridge 
in Server Satellite

Install IQNCCRS RS-232 Cartridges 
in the Client Satellites

NOTE:

 Refer to IQ3G-USA Cellular and 

IQNCCEN Ethernet Cartridge Installation 
Posters for full Installation instructions.

NOTE: 

Use Y-Cable for satellites that 

have both a CM Module and Radio.

What’s New

IQ-Cloud Sign Up

IQ-Cloud Login

EN

IQ-Cloud Support

(800) 254-0692  |  [email protected]

IQ-Cloud Login

Login

Configure this computer

Rain Bird IQ  Central Control System

TM

User Name

Password

I forgot my password

Log On

Cancel

What’s New

Show Quick Start

Select  Configure this computer 
for first time IQ-Cloud connection 
on a new computer.

Enter  User Name & Password to 
Logon to IQ-Cloud.

3G Cellular 
Antenna

Backplane

Connect DB9 Cable 
end to Radio port

Connect 2-pin cable 

end to CM Module

ESP-LX Controller

Server Satellite

IQ3G-USA or 

IQNCCEN Cartridge

Supplied IQ-Y and Straight Cables 
Connect Cartridges to CM's and Radios

IQFSCMLXME Flow Smart Connection Modules 

for ESP-LXME Controllers and IQCMLXD 

Connection Modules for LXD Controllers

To Internet 
and IQ-Cloud

To Additional 
Connection 
Module Client 
Satellites

To Additional 
Radio or 
Connection 
Module Client 
Satellites

IQNCCRS Cartridge

ESP-LX Controller

ESP-LX Controller

IQNCCRS Cartridge

19-Gauge PE 

Cable, Twisted Pair, 
Shielded, Gel Filled 

Communication 

Cable (Max 18K feet)

IQSSRADIO or RB-

SS-TN9B Radios 

(separate antenna 

and Radio Site 

Survey required)

Attach IQ-Y Cable to Radio 
IQ NCC Cartridges

Attach Straight-Cable for 
Connection Modules (CM)

Client Satellite

Отзывы: