Rain Bird ESP-Me Series Скачать руководство пользователя страница 2

Symbols

 

CAUTION: 

Symbol is intended to alert the user to 

important instructions or conditions that could

 

seriously affect irrigation effectivity or controller 
operation.

 

DIAL: 

Symbol indicates that the user is required to 

turn the dial on the controller to the appropriate

 

position in order to follow subsequent instructions 
as described in that section.

 

NOTE: 

Symbol is intended to alert the user to 

important operating functionality, installation or

 

maintenance instructions.

 

REPEAT: 

Symbol indicates that a repetition of 

previous steps or may be required in order to

 

continue or complete the controller programming 
process.

 

SPECIAL FEATURE AVAILABLE: 

Symbol indicates 

that a Special Feature is available for the dial

 

position. For more details ee Special Features 
section of the Advanced User Manual.

 

WARNING: 

Symbol alerts the user to the presence 

of electricity or electromagnetic energy which may

 

constitute a risk of electric shock, radiation exposure 
or other hazard.

 

Safety Information

 

WARNING: 

Date and time are retained by a lithium 

battery which is to be disposed of in accordance

 

with local regulations.

 

WARNING: 

Use only Rain Bird approved accessory 

devices. Unapproved devices may damage controller

 

and void warranty. For a list of compatible devices 
go to:

 

www.rainbird.com/controllersupport

 

WARNING

: You must use special precautions when 

valve wires (also known as station or solenoid

 

wires) are located adjacent to or share a conduit 
with other wires, such as wires used for landscape 
lighting, other “low voltage” systems or other “high 
voltage” power. Be sure to separate and insulate all 
conductors carefully taking care not to damage wire 
insulation during installation. An electrical “short” 
(contact) between the valve wires and another 
source of power can damage the controller and 
create a fire hazard.

 

NOTE

: This appliance is not intended for use by 

persons (including children) with reduced physical,

 

sensory or mental capabilities, or lack of experience 
and knowledge, unless they have been given 
supervision or instruction concerning use of the 
appliance by a person responsible for their safety.

 

Children should be supervised to ensure that 
they do not play with the appliance.

 

Disposal of Electronic Waste

 

In compliance with European Directive 2002/96/CE 
and EURONORM EN50419:2005, this device must 
not be thrown away with houshold garbage. This

 

device must be the object of an appropriate, selective 
removal procedure in order to recuperate it.

 

 

 

 
 

 

Questions?

 

In the USA or Canada call Rain Bird Technical Support at 
1-800-724-6247

 

or visit our web site at www.rainbird.com/controllersupport

 

 
 
 
 
 
 
 
 
 
 
 
 

 

    II 

ESP-Me User Manual      

 

Содержание ESP-Me Series

Страница 1: ...FRI 830 AM Rain Birdt ESP Me enhanced modularcontroller User Manual ...

Страница 2: ...anty For a list of compatible devices go to www rainbird com controllersupport c WARNING Youmustusespecialprecautionswhen valve wires also known as station or solenoid wires are located adjacent to or share a conduit with other wires such as wires used for landscape lighting other low voltage systems or other high voltage power Be sure to separate and insulate all conductors carefully taking care ...

Страница 3: ...ain Sensor WiredorWireless 10 Set Rain Sensor to Active after installing a rain sensor and removing jumperwireon backplane 10 Installing Optional Features Connect Optional Accessory 11 Remote Programming 11 Troubleshooting Battery Life 12 Reset Button 12 Error Detection 12 Programming Errors blinking LED 12 Electrical Errors non blinking LED 12 Clearing ElectricalError Alerts 12 Frequently AskedQu...

Страница 4: ...r Station or Program allows immediate watering of an individual station or an entire program l Test All Stations l Total Run Time Calculator by program l Sensor Bypass by Station Controls and Indicators Key operational features of the ESP Me Controller Test All Stations Manual Watering Rain Sensor Applies to all programs but can be set to bypass Programming Dial Rotate the dial to select programmi...

Страница 5: ...sh OFF Off NEXT Next Watering Day MO 1 Monday TU 2 Tuesday WE 3 Wednesday TH 4 Thursday FR 5 Friday SA 6 Saturday SU 7 Sunday DAY DD Day MONTH MM Month YEAR YY Year HOUR HH Hour MINUTE MM Minute 1 3 5 ODD 1 3 5 29 1 3 5 Odd Days 2 4 6 EVEN 2 4 6 30 2 4 6 Even Days STATION Station START TIME Start Time RUN TIME Run Time REMAINING RUN TIME Remaining Run Time SEASONAL ADJUST Seasonal Adjust DELAY Rai...

Страница 6: ...the desired program b NOTE Displayed run times are inclusive of any seasonaladjustmentmade Example Station1has a run time set for 10 minutes The program Seasonal Adjusted value is now set to 150 The new actual run time is 10 minutes x 150 15 minutes Rain Sensor Set the controller to obey or ignore a rain sensor SPECIAL FEATURE AVAILABLE The Rain Sensor setting applies to all programs and is not pr...

Страница 7: ...NTROLLER IN PROXIMITY TO ELECTRICAL POWER SOURCE AS REQUIRED Connect field wires Complete the installation GROUNDED ELECTRICAL OUTLET EXTERNAL POWER SOURCE If a Rain Sensor is installed turn the dial to Rain Sensor and set status to Active using the key Gather InstallationTools Before beginning installation gather the following tools and materials bNOTE The operating temperature range is 14 F to 1...

Страница 8: ...ance Only professional personnel shall install the controller Electrical Specifications 230V only Input 230VAC 0 2AMP 50 60Hz Output 25 5VAC 1 0AMP 50 60Hz Indoor Model 1 Route the transformer power cord through the conduit opening at the bottom left of the unit Knot the cable cord inside the controller cabinet to prevent it from being pulled out d CAUTION Donotroutethepowercordthroughthe field wi...

Страница 9: ...it shall be used for connecting main voltage to the controller Station ExpansionModules AdditionalStationModulescanincreasethenumberof available stations up to 22 Module Options Base Module included Expansion Modules sold separately For 120V 3 STATION ESPSM3 6 STATION ESPSM6 b NOTE 6 Stationmoduleiscompatibleonlywiththe ESP Me They are not backwards compatible withthe previous vintage controller b...

Страница 10: ...ed in Bay 4 only the first three station numbers assigned to that bay will be used and the unused numbers will be reserved for future use During programming the controller will skip any unused station numbers creating a gap in station numbering In our example a 3 Station module was installed in Bay 4 so stations 20 22 will be unavailable for programming During programming the missing stations will...

Страница 11: ...ughthesameopeningasthepowerwiring 1 Toperform a Valve Test connect the common wire to the COM terminal and the power wire to the VT terminal This will immediately turn the valve ON cWARNING The VT terminalisalwayspowered ON VT MV COM 5 6 7 11 12 13 17 18 19 1 2 3 4 8 9 10 14 15 16 20 21 22 VT MV COM 1 2 3 4 VT VALVE TEST CONNECT 120 VAC POWER COMMON MASTER VALVE 1 VT MV COM 5 6 7 11 12 13 17 18 19...

Страница 12: ... visit our website at www rainbird com controllersupport b NOTE Thiscontrollerisnotcompatiblewiththe Hunter PSR22 andPSR52 120 VAC JUMPER WIRES ON UNUSED STATIONS b NOTE DefaultruntimesforprogramAis10minutes for stations 1 4 d CAUTION ToavoidDeadHeadingyourpumpdo oneofthefollowingforallunusedstations module installed but not connected to a station wire l Connect jumper wire across unused stations ...

Страница 13: ... 20 21 22 VT MV COM CONNECT 120 VAC 1 2 3 4 VT VALVE TEST REMOVEAND DISCARD JUMPER WIRE The rain sensor symbol will show on the display in AUTO RUN or OFF when Rain Sensor is set to BYPASS SYMBOL SHOWN sun 427PM When Rain Sensor is set to ACTIVE no symbol is shown NO SYMBOL sun 427PM b NOTE For more details see Rain Sensor in the Advanced Options section of the Advanced User Manual b NOTE TheAlert...

Страница 14: ...r and void warranty Remote Programming Program the front panel remotely on battery power b HOMEOWNERNOTE Thefollowing donotrequirea9Vbatterytomaintain l Date and Time are maintained up to 10 years by an internal Lithium battery l ProgramsandSettingsarepermanentlystoredin controllers non volatile memory 11 ESP Me User Manual Installing Optional Features ...

Страница 15: ...e an alarm condition ALERT Programming Errors blinking LED Error Alert LED Error Message On Display No Start Times are set BLINK NO START TIMES No Run Times are set BLINK NO RUN TIMES No Watering Days are set BLINK NO WATER DAYS The ESP Me controller will reset or clear when the error is corrected b NOTE Thedial mustbein theAUTORUN position for an Alert message to appear on the display Electrical ...

Страница 16: ...ck circuit breaker and that unit is plugged into socket or properly connected to power source Controller may be plugged into a GFI outlet or an outlet that is wired to a GFI outlet Check power to the outlet or reset the circuit breaker Programmed schedules do not start Connected rain sensor may be activated Set Rain Sensor to BYPASS to ignore the rain sensor If watering resumes the sensor is opera...

Страница 17: ...cs Unplug the controller for 2 minutes then plug it back in If there is no permanent damage the controller should accept programming and resume normal operation Automatic error detection indicates a problem by Alert LED and an error message on display Short circuit or overload condition in valve master valve or pump start relay wiring Identify and repair the fault in the wiring Refer to compatible...

Страница 18: ...rence by the following measures Rain Bird Corporation 970 W Sierra Madre Azusa California 91702 U S A 626 963 9311 Rain Bird Europe 900rue Ampere BP 72000 13792 Aix en Provence CEDEX 3 FRANCE 33 04 42 24 44 61 Rain Bird International Inc 145 North Grand Avenue Glendora CA 91741 U S A 626 963 9311 Technical Services for U S and Canada only 1 800 RAINBIRD www rainbird com Reorient or relocate the re...