Verschlusstechnik

RAHRBACH

Instruction for Pin Locking Mechanism 7150

Note:

Please also read the assembly instructions for this product

Instructions regarding Rahrbach Series 7150 bolt closure

The information concerning the above article contained on these pages and on other data

carriers is based exclusively on a test carried out with this product and article. The infor-

mation given in the catalogue and on the Internet only serves to describe the product and

should not be understood as indicating warranted or guaranteed characteristics in the

legal sense. Information regarding product lifetime as well as definition of technical data is

provided in accordance with tests carried out internally at Rahrbach following generally re-

cognised regulations and/or standards.

The knowledge and information gained from such tests are unique and can change within

the framework of every application. Therefore the information which is published should

only be understood as a general guide. Safety regulations with regard to the specific loca-

tion where the product is to be used must be investigated in advance by the customer in

order that he may check the suitability of the product for the particular application himself.

We also recommend testing the product under the actual conditions in which it is to be

used in order to determine suitability.

Improper use, storage, maintenance, repair and/or actions or circumstances which may in-

fluence the product, or unsuitable further processing or treatment can lead to faults and

damage when the product is in use. We draw you attention to the fact that Rahrbach

GmbH does not accept any liability, guarantee or responsibility if our products are

changed, unless the change has been expressly approved by us for the specific case. If

there should be any questions, problems or unusual product behaviour or features when

the product is in use in the field, the door manufacturer or Rahrbach should be contacted

directly.

Use in accordance with the regulations

The bolt closure serves to prevent unauthorised opening of the sliding door from outside.

The Rahrbach bolt closure is only used for industrial applications on hand-operated sliding

doors, e.g. sliding doors of different sizes used for refrigeration rooms.

Operating Conditions:

Temperature:

up to 50°C - down to -25°C without heating system acceptable*

> - 25 °C only with heating system

Furthermore,please note the described indices mentioned in our mounting instructions

under "warning"!

Improper use

It is not permitted or not appropriate to use the bolt closure on fire doors, escape doors

and hatches, marked escape routes, electrically-operated sliding doors (except for Rahr-

bach product series 7150 with Reed Switch) and in the area of vehicle container design

and construction.

* is currently in validation of RAHRBACH test standart without heating system

General Advice:

After installing the bolt closure always check correct function with 2 people (one person

must be inside and one must be inside the refrigeration room).

For safety reasons, the user must be instructed in the use of the closure and should con-

firm in writing that the instruction has been received. Particular attention should be drawn

to the fact that when the door is opened from the inside the sliding bolt is pushed through

to the outside up to the stop. If the bolt is only partially pushed to the outside, the inside

release button can strike the frame when the door is opened and be damaged.

The key must be removed after every closing operation.

The luminous labels (pictograms) explain the use of the bolt closure. If these labels are

damaged or removed, a person wishing to operate the closure in the dark may not know

what to do and be reduced to experimentation. The pictograms must be located near the

assembled bolt closure.

Please read the following sections.

Security Advice:

The use of the bolt closure is only permitted, when it is guaranteed, that the bolt is not

blocked by freezing or its way is limited in the normal way.

If it is not able to preclude the possibility of thawing and refreezing because of various

temperature conditions, it has to be prevented with a technical solution e.g. an according

heating system or in an acceptable way with greasing with silicone grease.

Cleaning / Maintenance

The bolt closure is not maintenance-free.

The sliding bolt is greased with silicon grease against freezing. This grease may not be re-

moved. Regrease if necessary.

The bolt closure and the labels should be regularly checked to make sure that they are in

good condition and must be replaced immediately in case of damage. Any defects or dis-

turbances to operation must be repaired immediately or the item must be sent to the ma-

nufacturer for repair.

The customer is not permitted to undertake repairs himself.

The function of the closure must be checked at regular intervals at a temperature of max.

minus degrees. 

For cleaning of the bolt closure we recommend a mild cleaning agent, such as for exam-

ple soap and warm water. Other aggressive or abrasive cleaners must not be used.

Note: Clean the bolt at temperatures above freezing.

The cylinder may only be replaced by specialist or trained personnel.

Technical changes can lead to a change in liability risk.

Every manufacturer is therfore pleased to prove the suitability of this bolt closure on his

own. Distributor have to forward this instruction to the buyer. technical data sheet for locks

and closures.

Содержание 7150 Series

Страница 1: ...utes electrically operated sliding doors except for Rahr bach product series 7150 with Reed Switch and in the area of vehicle container design and construction is currently in validation of RAHRBACH t...

Страница 2: ...ction of locking position optional with reed relais 8 materials housing plastic bolt plastic nuts plastic button plastic profil cylinder brass screws stainless steel sealing rubber sealing grease unis...

Страница 3: ...always be opened after actuating the emergency opening mechanism The distance between door and frame must be 20 mm min and 35 mm max sealing thickness Series 7150 Follow Technical Data Sheet and Instr...

Страница 4: ...he outer side file a recess of 10 mm height and approx 3 mm width into the sheet in 3 o clock position to accept the little plate on the housing see arrow as a torsion safety mechanism Do not remove a...

Страница 5: ...inside 6 Mark three holes of nuts on the door centre punch and drill 3mm holes Insert 3 9 mm plate screws sup plied as a fixation of the nut thereby the pin locking mechanism is secured against disass...

Страница 6: ...ate it anti clockwise by about 180 1 Now the pin can be pushed inside 2 turn the key into vertical position again and take it out So the door is safeguarded against inad vertent opening Do not turn th...

Страница 7: ...o disassemble M5 threaded pin exchange cylinder e g towards cylinder out of a master key system retain cylinder again with threaded pin Regarding the door thickness use the optional 5mm spa cer for in...

Страница 8: ...chlusstechnik RAHRBACH Mounting Instruction for Pin Locking Mechanisms Series 7150 Follow Technical Data Sheet and Instructions Connect Reed Relais as shown in the datasheet Optional Reed relais funct...

Отзывы: