Model 2018E Operations Manual Rev Apr 2020 Page
17
of 39
2.6.2.3
OPTION JUMPER 3 – RED ENABLE MUST BE ACTIVE – RED EN
Configuration:
The installation of the Red Enable Must be Active (Option Jumper 3 – RED EN) jumper
determines if this feature is active. Special Function 1 and 2 inputs can be used to disable Red Fail monitoring, if
that function is needed while this feature is active.
Operations Modified:
Red Fail Monitoring
: When Red Enable Must be Active is enabled, the Red Enable input and at least
one Red input must be active or a red fail fault will be generated.
Typical Use
: This feature is used to force the use of the Red Interface cable. Without it, the Red Interface cable
could be left unplugged and the monitor would allow normal operations, just without red fail monitoring, dual
indication monitoring, short Yellow monitoring, and short clearance monitoring.
2.6.2.4
OPTION JUMPER 4 – MULTI INDICATION & SHORT YELLOW MONITORING –
MI/SY ON
Configuration:
The installation of the Multiple Indication and Short Yellow Monitoring (Option Jumper 4 –
MI/SY ON) jumper determines if this feature is active.
Operations Modified:
Dual Indication Monitoring
: When Multiple Indication and Short Yellow Monitoring is enabled, the
Dual Indication tests are always performed regardless of the state of the Red Enable input.
Short Yellow Monitoring
: When Multiple Indication and Short Yellow Monitoring is enabled, the
Short Yellow tests are always performed regardless of the state of the Red Enable input.
Short Clearance Monitoring
: When Multiple Indication and Short Yellow Monitoring is enabled, the
Short Clearance tests are always performed regardless of the state of the Red Enable input.
Typical Use
: This feature is useful when the user wants to ensure that the Multiple (Dual) Indication, Short
Yellow, and Short Clearance monitoring are always active. These functions are normally disabled when the Red
Enable input is not active.
2.6.3
FACTORY OPTIONS
2.6.3.1
GREEN FLASH (CANADIAN FAST FLASH)
Configuration:
This is a factory option and cannot be changed by the user. If this function is required but it is not
active, contact Reno A&E Technical Support for assistance. This feature is set to OFF for units sold in the United
States and set to ON for units shipped to Canada.
Operations Modified:
Please refer to Reno A&E Application Note AN-004 in the Support section of the Reno A&E web site
(renoae.com) under Monitor Support / Application Notes for a detailed description of how these tests are modified.
Red Fail Monitoring
: Red Fail Fault time is changed from 800 milliseconds to 1.5 seconds. Red Fail
Reset time is changed from 300 milliseconds to 200 milliseconds.
Dual Indication Monitoring
: Green-Yellow Dual Indication Reset time is changed from 300
milliseconds to 100 milliseconds. Green-Red Dual Indication Reset time is changed from 300
milliseconds to 100 milliseconds.
Typical Use
: This feature is intended to support the use of flashing Green indications as used in Canada.
2.6.3.2
FAST START UP
Configuration:
This is a factory option and cannot be changed by the user. If this function is required but it is not
active, contact Reno A&E Technical Support for assistance. This feature is set to OFF for all units unless
specifically requested to be turned on when ordered. NOTE: The same effect can be achieved by holding in the
front panel Reset switch while the monitor is powered up.
Operations Modified:
Monitor Power Up / Power Recovery
: When Fast Start Up is enabled, the four second delay is
removed and replaced with actual boot time (approximately 800 milliseconds). Also, if operating in
the 2010 mode of operation, the requirement for five watchdog transitions before exiting start up flash
is removed. Five watchdog transitions must still be detected before the ten second max power up
timer expires.
Typical Use
: Some agencies prefer that the monitor power up as fast as possible and allow normal operation of the
intersection as soon as possible to minimize flash time, especially if the monitor is plugged in while the
intersection is already running. Without this feature, the monitor will always take at least four seconds to power up