3.12 Connecting the ODUs
3.12.1
Connecting LFF, SFF, RADWIN 2000 Alpha INT, and Alpha
Connectorized ODUs
When working with the Alpha Connectorized ODU:
•
Hazardous 56VDC voltage may appear on accessible antenna connections. Use
Personal Protection Equipment (e.g. insulating gloves) when working with the
ODU or the antenna.
•
Connect the shield of the antenna coaxial cable to the protective earth when the
coaxial cable is used.
•
A skilled person should permanently connect the ODU to protective earth using
14 AWG wiring minimum.
1. Connect a CAT
‐
5e cable to the input port of the ODU as shown:
Figure 44 Input port: LFF ODU (connection label: "IDU")