RADWIN
5000
HPMP
User
Manual
Release
3.5.70
23
‐
2
Calculations
•
Maximum
linear
input
power
(used
to
calculate
minimum
distance)
•
Antenna
gain
and
cable
loss
for
ODU
with
integrated
antenna
•
Available
Channel
Bandwidths
Calculations
EIRP
Expected
RSS
and
Fade
Margin
where:
Site
A
is
the
transmitting
site
Site
B
is
the
receiving
site
PathLoss
is
calculated
according
to
the
free
space
model,
where
Sensitivity
is
dependent
on
air
‐
rate.
Min
and
Max
Range
MinRange
is
the
shortest
range
for
which
per
air
‐
rate.
MaxRange
(with
Adaptive
checked)
is
the
largest
range
for
which
,
at
the
highest
air
‐
rate
for
which
this
relationship
is
true.
In
a
link
with
adaptive
rate
this
will
be
the
actual
behavior.
MaxRange
(for
a
given
air
‐
rate)
is
the
largest
range
for
which
.
Service
The
Ethernet
and
configured
TDM
trunks
throughput
is
calculated
according
to
internal
product
algorithms.
Availability
The
Service
Availability
calculation
is
based
on
the
Vigants
Barnett
method
which
predicts
the
downtime
probability
based
on
a
climate
factor
(C
factor).
EIRP
TxPower
AntennaGain
SiteA
CableLoss
SiteA
–
+
=
ExpectedRSS
EIRP PathLoss
AntennaGain
SiteB
CableLoss
SiteB
–
+
–
=
PathLoss
32.45 20
frequency
MHz
20
RequiredRange
Km
10
log
+
10
log
+
=
ExpectedFadeM
in
arg
ExpectedRSS Sensitivity
–
=
ExpectedRSS
MaxInputPower
ExpectedRSS
Sensitivity
ExpectedRSS
Sensitivity
RequiredFadeM
in
arg
+
Содержание 5000 HPMP
Страница 1: ...USER MANUAL RADWIN 5000 POINT TO MULTIPOINT BROADBAND WIRELESS Release 3 5 70...
Страница 21: ...Part 1 Basic Installation Release 3 5 70...
Страница 69: ...Part 2 Sector Installation Release 3 5 70...
Страница 155: ...Part 3 Sector Management Release 3 5 70...
Страница 191: ...RADWIN 5000 HPMP User Manual Release 3 5 70 8 36 Inventory Inventory You should note the details for each HSU...
Страница 193: ...RADWIN 5000 HPMP User Manual Release 3 5 70 8 38 Date Time Date Time The functionality is identical as that for the HBS...
Страница 197: ...RADWIN 5000 HPMP User Manual Release 3 5 70 8 42 Nomadic...
Страница 252: ...RADWIN 5000 HPMP User Manual Release 3 5 70 11 8 Registering HMUs 3 Open the Air Interface tab...
Страница 290: ...Part 4 Site Synchronization Release 3 5 70...
Страница 319: ...RADWIN 5000 HPMP User Manual Release 3 5 70 16 7 Configuring the GSU...
Страница 320: ...Part 5 Advanced Installation Topics Release 3 5 70...
Страница 354: ...Part 6 Field Installation Topics Release 3 5 70...
Страница 387: ...RADWIN 5000 HPMP User Manual Release 3 5 70 25 12 Configure If you change any of these fields you will cause a HBS reset...
Страница 395: ...RADWIN 5000 HPMP User Manual Release 3 5 70 25 20 WEB Interface for VMUs The current position is marked with the icon...
Страница 396: ...Part 7 Product Reference Release 3 5 70...
Страница 510: ...RADWIN 5000 HPMP User Manual Release 3 5 70 F 5 Montage sur un mur Montage sur un mur Figure F 5 Montage sur un mur...
Страница 517: ......