RADWIN
5000
HPMP
User
Manual
Release
3.5.70
8
‐
1
Chapter
8:
Managing
the
Sector
Scope
of
this
Chapter
This
chapter
deals
with
managing
the
sector
from
the
HBS.
It
covers
HBS
Configuration
and
HSU
Configuration
from
the
HBS.
HSU
direct
or
over
‐
the
‐
air
configuration
is
a
little
different
and
is
covered
in
A
Configuration
window
is
available
for
both
the
HBS
and
the
HSUs
to
change
setting
without
necessarily
dropping
service.
Nevertheless
care
must
be
exercised
when
changing
them.
By
way
of
example,
changing
antenna
parameters
for
a
HSU
results
in
a
HSU
reset.
It
is
necessary
however
to
have
this
function
in
the
Configuration
window
since
it
is
required
to
initially
set
up
the
unit.
The
HBS
itself
may
be
configured
over
‐
the
‐
air:
A
scenario
for
this
is
where
the
sector
is
back
‐
hauled
by
on
of
the
HSUs.
There
are
no
significant
differences
between
the
two
methods,
however
some
care
is
required.
If
for
example,
you
deactivate
the
HBS
over
‐
the
‐
air,
you
will
lock
yourself
out
of
the
sector.
Running
Spectrum
View
from
the
HBS
manager
over
‐
the
‐
air,
will
lock
you
out
for
the
duration
of
the
Spectrum
View
timeout
period.
Configuring
a
HBS
Configuration
Menu
Buttons
Open
the
Configuration
window.
Содержание 5000 HPMP
Страница 1: ...USER MANUAL RADWIN 5000 POINT TO MULTIPOINT BROADBAND WIRELESS Release 3 5 70...
Страница 21: ...Part 1 Basic Installation Release 3 5 70...
Страница 69: ...Part 2 Sector Installation Release 3 5 70...
Страница 155: ...Part 3 Sector Management Release 3 5 70...
Страница 191: ...RADWIN 5000 HPMP User Manual Release 3 5 70 8 36 Inventory Inventory You should note the details for each HSU...
Страница 193: ...RADWIN 5000 HPMP User Manual Release 3 5 70 8 38 Date Time Date Time The functionality is identical as that for the HBS...
Страница 197: ...RADWIN 5000 HPMP User Manual Release 3 5 70 8 42 Nomadic...
Страница 252: ...RADWIN 5000 HPMP User Manual Release 3 5 70 11 8 Registering HMUs 3 Open the Air Interface tab...
Страница 290: ...Part 4 Site Synchronization Release 3 5 70...
Страница 319: ...RADWIN 5000 HPMP User Manual Release 3 5 70 16 7 Configuring the GSU...
Страница 320: ...Part 5 Advanced Installation Topics Release 3 5 70...
Страница 354: ...Part 6 Field Installation Topics Release 3 5 70...
Страница 387: ...RADWIN 5000 HPMP User Manual Release 3 5 70 25 12 Configure If you change any of these fields you will cause a HBS reset...
Страница 395: ...RADWIN 5000 HPMP User Manual Release 3 5 70 25 20 WEB Interface for VMUs The current position is marked with the icon...
Страница 396: ...Part 7 Product Reference Release 3 5 70...
Страница 510: ...RADWIN 5000 HPMP User Manual Release 3 5 70 F 5 Montage sur un mur Montage sur un mur Figure F 5 Montage sur un mur...
Страница 517: ......