RADWIN
5000
HPMP
User
Manual
Release
3.5.70
6
‐
1
Chapter
6:
Installing
the
Sector
Scope
of
this
Chapter
offered
an
overview
of
a
running
Sector
as
motivation
for
the
technical
installation
details
set
out
below.
Assuming
that
the
Sector
equipment
is
in
place
as
described
in
earlier
chapters,
sector
installation
has
two
phases:
•
Configuring
and
activating
the
HBS
•
Bringing
up
the
HSUs
‐
configuration
and
registration
The
same
RADWIN
Manager
program
is
used
for
both
the
HBS
and
the
HSUs.
Much
of
the
process
is
common
to
both
types
of
ODU.
We
will
cover
the
HBS
in
detail;
for
the
HSUs
we
will
concentrate
on
those
items
which
are
different.
In
any
event,
where
setup
procedures
are
common
we
will
point
them
out.
This
chapter
covers
fixed
and
nomadic
HSU
configurations.
Mobile
HSUs
are
covered
in
.
Concepts
A
HBS
out
of
the
box,
must
be
configured
with
•
Basic
RF
parameters
such
as
frequency
band,
channel
bandwidths
and
Sector
ID
•
Networking
parameters
such
as
IP
address,
subnet
mask
and
default
gateway
At
this
point,
the
HBS
is
in
an
inactive
state,
powered
up,
configurable
but
not
transmitting
anything.
Upon
activation
,
the
HBS
will
commence
transmitting
and
receiving
packets
related
to
sector
management
only
‐
that
is
no
service.
Activation
and
Deactivation
are
effected
quite
simply
by
clicking
a
toggle
button.
Assuming
that
the
Sector
HSUs
are
mounted
aligned
and
powered
up,
the
HSUs
will
discover
the
HBS
establishing
links
for
management
only.
At
this
point
the
HSUs
may
be
managed
over
the
air.
Содержание 5000 HPMP
Страница 1: ...USER MANUAL RADWIN 5000 POINT TO MULTIPOINT BROADBAND WIRELESS Release 3 5 70...
Страница 21: ...Part 1 Basic Installation Release 3 5 70...
Страница 69: ...Part 2 Sector Installation Release 3 5 70...
Страница 155: ...Part 3 Sector Management Release 3 5 70...
Страница 191: ...RADWIN 5000 HPMP User Manual Release 3 5 70 8 36 Inventory Inventory You should note the details for each HSU...
Страница 193: ...RADWIN 5000 HPMP User Manual Release 3 5 70 8 38 Date Time Date Time The functionality is identical as that for the HBS...
Страница 197: ...RADWIN 5000 HPMP User Manual Release 3 5 70 8 42 Nomadic...
Страница 252: ...RADWIN 5000 HPMP User Manual Release 3 5 70 11 8 Registering HMUs 3 Open the Air Interface tab...
Страница 290: ...Part 4 Site Synchronization Release 3 5 70...
Страница 319: ...RADWIN 5000 HPMP User Manual Release 3 5 70 16 7 Configuring the GSU...
Страница 320: ...Part 5 Advanced Installation Topics Release 3 5 70...
Страница 354: ...Part 6 Field Installation Topics Release 3 5 70...
Страница 387: ...RADWIN 5000 HPMP User Manual Release 3 5 70 25 12 Configure If you change any of these fields you will cause a HBS reset...
Страница 395: ...RADWIN 5000 HPMP User Manual Release 3 5 70 25 20 WEB Interface for VMUs The current position is marked with the icon...
Страница 396: ...Part 7 Product Reference Release 3 5 70...
Страница 510: ...RADWIN 5000 HPMP User Manual Release 3 5 70 F 5 Montage sur un mur Montage sur un mur Figure F 5 Montage sur un mur...
Страница 517: ......