![Radware DefensePro VA Скачать руководство пользователя страница 63](http://html1.mh-extra.com/html/radware/defensepro-va/defensepro-va_installation-and-maintenance-manual_3358622063.webp)
DefensePro VA Installation and Maintenance Guide
DefensePro VA Installation and Configuration
Document ID: RDWR-DPVA_IG2005
63
Note:
Optimize the VM for best DefensePro VA performance. Radware recommends optimizing
the VM running DefensePro VA as follows:
—
Pinning the DefensePro VA vCPUs to physical cores/hyperthreads and not let them be shared
with other VMs, and to prevent the hypervisor from moving them. Memory over-subscription
is discouraged.
—
In a hyperthreaded environment, it is best to configure an even number of DefensePro
engines and allocate whole physical cores (both hyperthreads on each physical core) for
DefensePro VA, and not mix them with other VMs.
—
On a host with multiple CPUs using the NUMA architecture, Radware recommends assigning
all DefensePro VA vCPUs to cores/hyperthreads on the same NUMA node.
Core Pinning
In order to optimize performance, it is suggested to set core pinning in VMware.
a. In the virtual machine, go to the
Resource
tab.
b. Select
Advanced CPU
.
c. In the
Hyperthread Core Sharing
area, set the
Mode
parameter to
Internal
.
d. In the
Scheduling Affinity
area, enter the physical processor affinity (CPU Pinning) range.
(For example, 10-19, as shown in the screen below.)
Содержание DefensePro VA
Страница 1: ...DefensePro VA INSTALLATION AND MAINTENANCE GUIDE Document ID RDWR DPVA_IG2005 May 2020...
Страница 2: ...DefensePro VA Installation and Maintenance Guide 2 Document ID RDWR DPVA_IG2005...
Страница 26: ...DefensePro VA Installation and Maintenance Guide 26 Document ID RDWR DPVA_IG2005...
Страница 30: ...DefensePro VA Installation and Maintenance Guide Preface 30 Document ID RDWR DPVA_IG2005...