![RADWAG PUE HX7 Скачать руководство пользователя страница 10](http://html2.mh-extra.com/html/radwag/pue-hx7/pue-hx7_user-manual_3386998010.webp)
10
4.4. Inputs / Outputs
Standard HX7 indicator is equipped with 4 optoisolated inputs and 4
semiconductor outputs (semiconductor relays). The signals are fed through
M12 8P connectors.
4OUTPUTS
Pin1 – OUT1
Pin2 – OUT2
Pin3 – WY3
Pin4 – OUT4
Pin5 – COM
Pin6 – 24VDC
Pin7 – GND
Pin8 – NC
4INPUTS
Pin1 – IN1
Pin2 – IN2
Pin3 – IN3
Pin4 – IN4
Pin5 – COM
Pin6 – 24VDC
Pin7 – GND
Pin8 – NC
4.4.1. Technical Specifications
Output parameters
Output quantity
4
Output type
Solid-state relay
Cable cross-section
0.14 - 0.5mm
2
Maximum output current
0.5A DC
Maximum output voltage
30VDC, AC
Input parameters
Input quantity
4
Input type
Optoisolated
Cable cross-section
0.14 – 0.5mm
2
Input voltage range
5 -24VDC