background image

 

7

 

 

To  clean  polished  surfaces,  make  circular  movements.  After  removing  all  dirt, 
polish the surface with a dry cloth to dry the surfcae and make it glow.

 

 
 

4.  SERVICE AND REPAIRS 

 

 

If  you  can  notice  any  damage,  unplug  the  device 
immediately.  Damaged  element  must  be  immediately 
replaced or repaired by RADWAG service technicians.

 

 

If the scale malfunctions, contact the manufacturer’s local service center.

 

 

In  case  of  any  defect,  the  operator  must  supply  the  defective  device  to  the 
manufacturer’s service center or, if impossible, report the defect to the service 
center to arrange the scope and method of repair.

 

 

 

The operator is not allowed to repair the product in any way. 
Any  unauthorized  manipulations  (modifications,  repairs, 
etc.) 

shall 

invalidate 

certificates, 

declarations 

and 

guarantees of the manufacturer.

 

 
 

5.  DISPOSAL 

 

Scales  must  be  recycled  and  are  not  considered  as  household  waste.  
The  product  must  be  disposed  of  when  its  life  ends  in  accordance  with 
applicable law.

 

 

 

 
 

6.  STRUCTURE 

 

CY10  are  single-sensor  scales  intended  to  quickly  and  precisely  measure 
masses up to 300 kg. In single-sensor scales, mass is measured by one mass 
sensor located in the structure of the platform.  

 

Platforms are equipped with a stainless steel weighing pan and, depending on 
the  scale  type,  star-piece  structure  and  foundation  that  is  made  of  stainless 
steel or painted.

 

Содержание CY10

Страница 1: ...CY10 MULTIFUNCTIONAL SCALES OPERATING MANUAL ITKU 134 01 02 23 EN...

Страница 2: ...2 FEBRUARY 2023...

Страница 3: ...V radiation substances that cause chemical reactions The device must not be used in explosive atmospheres gas or dust Do not use sharp tools e g knife screwdriver etc to use the touch panel In case of...

Страница 4: ...5 DISPOSAL 7 6 STRUCTURE 7 6 1 Dimensions 8 6 2 Description of Connectors 10 7 INSTALLATION 11 7 1 Unpacking and Assembly 11 7 1 1 CY10 D2 Series Scales 11 7 1 2 CY10 xx K Series Scales 12 7 2 Scale L...

Страница 5: ...presentatives of the manufacturer and user C RADWAG shall not be held responsible for defects or losses deriving from unauthorized or improper production or servicing D The guarantee does not cover th...

Страница 6: ...parations Always remove dirt with a microfiber cloth so that protective coatings of the elements cannot be damaged In case of daily care and stain removal follow the steps below 1 Remove dirt with a c...

Страница 7: ...the scope and method of repair The operator is not allowed to repair the product in any way Any unauthorized manipulations modifications repairs etc shall invalidate certificates declarations and guar...

Страница 8: ...8 Single sensor scale components general view Single sensor scale components general view 1 Weighing pan 2 Star piece 3 Mass sensor 4 Foundation 6 1 Dimensions CY10 D2 scales dimensions...

Страница 9: ...9 CY10 F1 K scales dimensions CY10 C2 K scales dimensions...

Страница 10: ...10 CY10 C3 K scales dimensions 6 2 Description of Connectors 1 Reboot or on off button 2 Left loudspeaker 3 Right loudspeaker 4 USB type A port 5 USB type A port...

Страница 11: ...tive sensors 15 Camera 16 Camera LED light 17 Signal LED light 18 Weighing platform cable glands 7 INSTALLATION 7 1 Unpacking and Assembly 7 1 1 CY10 D2 Series Scales A Remove the scale from the facto...

Страница 12: ...the feeder cable into the mains socket and put the feeder cable plug into the port at the back of the weighing indicator housing The operating system and RADWAG software loading procedure will initiat...

Страница 13: ...will restart and device will reload 8 HOME PAGE The home page can be divided into 5 fields The upper part of the screen shows information on current working mode logged user date time active connectio...

Страница 14: ...software manual At the bottom of the screen you can see permanent functional buttons 9 NAVIGATION IN THE MENU Navigation in the menu is intuitive and user friendly Thanks to the touch screen display i...

Страница 15: ...r going back to the home screen Procedure Press button a couple of times to make the scale return to home screen Press in the lower bar to return to home page immediately 10 WEIGHING Load the weighing...

Страница 16: ...ing pan Avoid side loads of the scale particularly side strokes 11 CONNECTION WIRE DIAGRAMS Scale computer wire RS232 Scale printer wire RADWAG ZEBRA To assure correct cooperation with peripherals wit...

Страница 17: ...rnet wire is a standard network cable that ends on both sides with RJ45 tip 12 TECHNICAL PARAMETERS Technical parameters of particular scales are available on the following website www radwag pl 13 ER...

Страница 18: ...18...

Отзывы: