Setting up the MCU | 26
RADVISION | Installation Guide for SCOPIA Elite 5100 Series MCU Version 7.7
Figure 4-12
Securing the MCU to the rack
Attaching the System Ground
Note:
WARNING - Before connecting power to the device or turning it on, provide it with an adequate
connection to a grounding point at the site. Contact the appropriate electrical inspection authority
or an electrician if you are uncertain that suitable grounding is available on the site.
The MCU grounding stud is located on the rear panel.The grounding equipment is user supplied.
Make sure to use an18 AWG (1 mm
2
) or larger grounding wire and appropriate grounding lug. The
length of the grounding wire depends on the MCU location or on the site environment.
Connecting Cables to the Device
Follow the safety guidelines described in the Safety Guide during this procedure, and use the
power, network, and serial cables supplied with the accessories kit.
Procedure
Step 1
Connect the power cable:
a.
Turn off the power distribution unit (PDU).