Radionics Security System 8112 Скачать руководство пользователя страница 1

Page Code

Table of Contents

Introduction
Command Center Function Keys
Security System Basics
Your Custom Display
View Faulted or Bypassed Points
Warning Displays and Tones
Fire Alarms
Burglary Alarms
Fire Trouble Event
Silencing Fire Troubles
Special Fire Trouble Display
Viewing Fire Troubles
Non-Fire Trouble Events
Silencing Non-Fire Trouble Events
Viewing Non-Fire Trouble Events
Special System Trouble Display
Cleared Events Are Not Lost
Entry Delay Tone and Display
Exit Delay Tone and Display
Keystroke Checking Tones
Silencing an Alarm
How Your System Reports Alarms
System Commands & Functions
Turning the System On (Arming)
Turning the System Off (Disarming)

Page Code

Turning the System On (Arming)

With a Duress Passcode

Turning the System On (Arming)

With Doors or Windows Open

MASTER ARM ?

COMMAND 1

MASTER ARM INST ?

COMMAND 11

PERIMETR INST ?

COMMAND 2

PERIMETR DELAY ?

COMMAND 3

Silence the Trouble Sounder &

Clear Trouble Display

COMMAND 4

VIEW MEMORY ?

COMMAND 40

WALK TEST ?

COMMAND 44

RESET SENSORS?

COMMAND 47

WATCH MODE ?

COMMAND 6

PERIMETR PART?

COMMAND 8

Special Alerts

COMMAND 7
COMMAND 9

Security System Limitations
Fire Safety and Evacuation
Standard Displays
System Trouble Displays
Security System Glossary
Maintenance and Service
How to Clean the Command Center

Содержание Security System 8112

Страница 1: ...ing an Alarm How Your System Reports Alarms System Commands Functions Turning the System On Arming Turning the System Off Disarming Page Code Turning the System On Arming With a Duress Passcode Turning the System On Arming With Doors or Windows Open MASTER ARM COMMAND 1 MASTER ARM INST COMMAND 11 PERIMETR INST COMMAND 2 PERIMETR DELAY COMMAND 3 Silence the Trouble Sounder Clear Trouble Display COM...

Страница 2: ... 5 6 7 4 A R E A X I S O F F PREV ESC ENT 1 ALL RESET WATCH SPECIAL C O M M A N D M E N U YES NEXT PARTIAL POLICE BYPASS INSTANT DELAY ALPHA NUMERIC DISPLAY DIGITAL KEYPAD FUNCTION KEYS SIREN SPEAKER COMMAND BAR ...

Страница 3: ...are programmed by your security company Some of them may not be included in your system Some of the functions covered may require you to enter your personal passcode Throughout this guide the symbol refers to a variable numerical quantity such as the number of points to test or exit delay time Messages that appear in the command center display appear in this guide LIKE THIS Keys that you must pres...

Страница 4: ... will not recognize your passcode until you press ENT The second function of the ENT YES key is to select the menu item displayed Some menu items require your personal passcode be entered before starting the function Remember to press ENT after entering your passcode ESC MENU The ESC Escape MENU key has two functions First the ESC MENU key is used to enter the Command Menu Pressing this key when a...

Страница 5: ...nding upon whether the system is turned on armed or turned off disarmed Controlled points are programmed to respond instantly to alarm conditions or to provide a delay for you to reach the command center and disarm the system The words A1 ALARMS appear before the point text when there is an alarm There are two types of controlled points perimeter points and interior points Perimeter Points These p...

Страница 6: ...annot be disarmed You can clearly distinguish fire points from other non fire points at the command center When there is a fire alarm the text identifying the point as a fire point is displayed pressing the PREV key causes the summary display such as A1 FIRE ALARM to appear in the display and pressing NEXT displays any other points in alarm Fire alarms have a unique audible warning signal Non Fire...

Страница 7: ...ur security company may have programmed custom text for the idle displays in your system The custom text and the default text for the three system idle displays follow Custom Displays Default Text Function _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ AREA _ IS ON Indicates the area is turned on armed and ready to detect intruders _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ AREA _ IS OFF Indicates the area is turned off di...

Страница 8: ...t appear Instead the display shows NO FAULTS BYPAS 3 You can return to idle text at any time by pressing ESC View Faulted or Bypassed Points To properly arm your system all the doors and windows in the system must be in the normal not faulted condition Viewing the faulted points helps you find faulted points and correct them so proper arming is possible Your command center offers two ways of displ...

Страница 9: ... be connected to your system Bells or sirens mounted on the exterior of your premises alert neighbors to emergencies and provide an audible guide for police and fire fighters Command Center Quiets for Keystrokes Pressing any key on the command center lights the keys and quiets any warning tones If you don t press another key within 20 seconds the keypad lights go out and the warning tones resume P...

Страница 10: ...tem if it was armed The system will now display ALARM SILENCED and then the number of points in alarm A1 FIRE ALARM and the custom text of all the points in alarm in the order of occurrence Your system may be programmed so that you cannot silence some fire alarms until the fire event clears Entering COMMAND 4 clears the scrolling point text from the display The ALARM SILENCED message will continue...

Страница 11: ...ne The tone sounds for the time set by your security company The command center display shows the number of burglary points activated A1 ALARMS and then custom text for each activated point Press NEXT to manually scroll the list if you wish Events scroll from the oldest to the newest Silencing Burglary Alarms Entering a personal passcode with the proper authority level silences a burglary alarm an...

Страница 12: ...Display If you silence the command center or clear a trouble for a Fire Point from the display and the fire point remains in trouble FIRE TROUBLE appears in the command center s display FIRE TROUBLE remains in the display until the condition causing the trouble is cleared Note Some fire points when tripped will display FIRE TROUBLE for a preset amount of time If no other fire activity is detected ...

Страница 13: ...l passcode with the proper authority level silences a trouble and disarms the panel if it was armed If you wish to clear the scrolling trouble message from the display enter COMMAND 4 If you wish to review these cleared troubles this can be done by using COMMAND 40 Viewing Non Fire Trouble Events After you enter your passcode the text of the activated points continues to automatically scroll throu...

Страница 14: ... tone displays EXIT NOW and counts down the exit delay time Special System Trouble Display SERVC AC FAIL and SERVC BATT LOW are examples of system trouble displays These displays appear on all keypads in the system All system trouble displays begin with SERVC See Standard Displays for a description of each system trouble display Entering your passcode or a COMMAND 4 will silence a system trouble t...

Страница 15: ... and press ENT To SILENCE an alarm Enter your passcode and press ENT How Your System Reports Alarms Your security system may be programmed to automatically disconnect your telephones when sending reports to your security company Once the report is completed your security system returns the telephones to normal operation check with your security company Your system makes repeated attempts to send r...

Страница 16: ...function then NOT AUTHORIZED will display on the Command Center Press the COMMAND bar and then the one or two digits shown in the table below to perform the function When you use a command to perform a function the displays in the function list below do not appear at your command center Command Function CMD 1 MASTER ARM CMD 1 1 MASTER ARM INSTANT CMD 2 PERIMETER INSTANT CMD 3 PERIMETER DELAY CMD 4...

Страница 17: ... to arm the entire system The simplest way to arm your system is to enter your personal passcode or COMMAND 1 There are several other arming commands to turn the system on These are described later in this guide To Turn Your Security System On Arm 1 Enter your passcode and press ENT 2 The command center briefly displays ARMING and the exit delay tone begins After exit delay time expires the displa...

Страница 18: ...he delay time expires and the system will turn off If you enter through the wrong door or fail to disarm before the entry delay time expires you will cause an alarm If this happens silence the alarm by entering your personal passcode and pressing ENT and call your security company to let them know that it is not an emergency situation To Turn Your Security System Off Disarm 1 Enter your personal p...

Страница 19: ...our passcode or an arming function to start the arming process 2 The display shows CHK AREA X 3 Press NEXT repeatedly to scroll through the point text for each faulted point FORCE ARM displays after the text for the last faulted point Turning the System On Arming With a Duress Passcode Your passcode may have a special duress feature that is simply your personal passcode with its last digit increas...

Страница 20: ... system is programmed not to arm with particular points faulted doors or windows open TOO MANY BYPASSD Indicates that the system s number of allowable bypassed points has been reached Your system s maximum number of bypassed and or force armed points is set by your security company Check with them to learn this number TOO MANY FAULTED Indicates that more than the number of allowable points are fau...

Страница 21: ... cleaning service a serviceman or others to turn on your system when they leave 1 Using Master Arm 1 The display shows disarmed idle text 2 Press the COMMAND bar The display shows SYSTEM COMMAND 3 Press the 1 key Note If you prefer you may use the Command Menu in place of steps 2 and 3 to initiate this function Press the MENU key to enter the Command Menu then press NEXT repeatedly until you reach...

Страница 22: ......

Страница 23: ...r the Command Menu then press NEXT repeatedly until you reach the MASTER ARM INST prompt Press ENT 4 The display shows ALL SECURE 5 To disarm your security system enter your personal passcode and press ENT 11 MASTER ARM INST COMMAND 11 Turn the Entire System On Without Delays Description Use this function to turn on the entire system both perimeter and interior without delays When entering COMMAND...

Страница 24: ......

Страница 25: ...ays when you use this function You must disarm turn off the system to enter or exit the premises 2 Using Perimetr Inst 1 Interior points are not armed with this command and may remain faulted while arming with COMMAND 2 2 Press the COMMAND bar The display shows SYSTEM COMMAND 3 Press the 2 key Note If you prefer you may use the Command Menu in place of steps 2 and 3 to initiate this function Press...

Страница 26: ...PERIMETR INST continued 5 To disarm your security system enter your personal passcode and press ENT ...

Страница 27: ...ay expires PERIMETR DELAYED is displayed 5 To disarm your security system enter your personal passcode and press ENT 3 PERIMETR DELAY COMMAND 3 Turn On the Perimeter With Delays Description In residential systems this function allows you to only arm the perimeter and exit through a door programmed for exit delay The interior of the building remains disarmed People or pets are free to move througho...

Страница 28: ......

Страница 29: ...events This command also clears system messages from the display The ALARM SILENCED display may continue to scroll to remind you that cleared events can be seen with the View Memory function seeView Memory Using COMMAND 4 1 Press the COMMAND bar The display shows SYSTEM COMMAND 2 Press the 4 key The Command Center sounder is silenced ...

Страница 30: ......

Страница 31: ...he COMMAND bar The display shows SYSTEM COMMAND 3 Press the 4 key followed by the 0 key Note If you prefer you may use the Command Menu in place of steps 2 and 3 to initiate this function Press the MENU key to enter the Command Menu then press NEXT repeatedly until you reach the VIEW MEMORY prompt Press ENT 4 Your system displays event summary lines and point text in this order fire alarm summary ...

Страница 32: ......

Страница 33: ... the 4 minute period the command center will appear to go dead If this happens contact your security company At the end of the 4 minute period AC is returned to the system and the panel restores To test individual 44 detection devices simply activate sensors and open protected doors and windows one at a time As each detection device is faulted the Command Center emits a brief tone and the display ...

Страница 34: ... see the points that remain untested When point text is displayed press ESC The display shows PTS TO TEST Press the ESC key VIEW UNTESTED is displayed Press ENT The display shows PTS UNTESTED Press NEXT to see a list of the points that have not yet been tested Move through this list by pressing the NEXT key To resume the Walk Test press ESC PTS UNTESTED is displayed Press ESC PTS TO TEST is displa...

Страница 35: ...oke fire or other danger present If you can t reset the detector or sensor contact your security company RESET SENSORS COMMAND 47 Reset Sensors Description Detection devices such as smoke detectors and shock sensors must be reset after being activated This function momentarily removes power from these sensors to reset them It also clears point information from the display leaving the ALARM SILENCE...

Страница 36: ......

Страница 37: ...serve as a door chime to alert you when a customer or delivery person enters your business Note Contact your security company to find out which points are watch points and whether or not your system automatically turns the Watch Mode on whenever you disarm 6 Entering Watch Mode 1 Ensure your command center is at disarmed idle text 2 Press the COMMAND bar The display shows SYSTEM COMMAND 3 Press th...

Страница 38: ... Note If you prefer you may use the Command Menu in place of steps 2 and 3 to initiate this function Press the MENU key to enter the Command Menu then press NEXT repeatedly until you reach the WATCH MODE prompt Press ENT 4 The display briefly shows WATCH IS NOW OFF before returning to idle disarmed text ...

Страница 39: ...l systems when you need access to the large overhead doors to receive deliveries using this function will allow you to keep the rest of the building perimeter armed 8 Using Perimetr Part 1 Ensure that the command center shows disarmed idle text Before using this function decide which points are to be left turned off Fault the points doors and windows by leaving them open The points must remain ope...

Страница 40: ...ed 5 When performing a COMMAND 8 and no points are faulted or if the points return to normal before the exit delay time expires the system is turned on as in COMMAND 3 6 To disarm enter your personal passcode and press ENT ...

Страница 41: ..._____________________________________________ __________________________________________________________________ __________________________________________________________________ 7 9 Special Alerts COMMAND 7 and COMMAND 9 Description COMMANDs 7 and 9 can be programmed to respond to a choice of numerous situations that may need immediate attention They may also be used to send a silent alarm to yo...

Страница 42: ...y your alarm company ___ ring a bell on your premises ___ display at your command center Description ___________________________________________________ __________________________________________________________________ __________________________________________________________________ __________________________________________________________________ ...

Страница 43: ... will not detect intrusion Smoke detectors cannot detect smoke in chimneys walls or roofs or smoke blocked by a closed door They may not detect smoke or fire on a level of the building different from the one on which they are located Smoke detectors may not be able to warn in time about fires started by explosions improper storage of flammables overloaded electrical circuits or other types of haza...

Страница 44: ...ay decorations are some of the common causes of household fire 2 Install a fire alarm system The primary purpose of this system is to protect lives by giving the earliest possible warning of danger 3 A smoke detector indicated in the figure by an inverted s in a circle should be provided to protect each sleeping area in a home 4 Practice an escape plan Because there may be very little time between...

Страница 45: ...scending outside the building if one does not already exist As a part of this plan all family members should arrange to meet at a location away from the house such as a neighbor s house so you will know that everyone is accounted for If it is determined that the alarm was accidentally sounded the bell should be silenced the detectors reset and your security company notified immediately that there ...

Страница 46: ...tandard Displays Your command center uses standard and custom displays to show the status of the security system Many standard displays are described below Your system may not use all of them Descriptions of your custom text follow SYSTEM COMMAND Displays when you press the COMMAND bar The system is waiting for you to enter a one or two digit number to complete the command DISARM NOW When the syst...

Страница 47: ...ommand center other than the one displaying the message is in a trouble condition Notify your security company System Trouble Displays If you see any of the system trouble displays shown below contact your security company to determine whether repairs are needed CALL FOR SERVICE Call your security company Your security system may have failed SERVC PANEL Indicates a problem with the panel The panel...

Страница 48: ...selected Contact your security company if you have questions or the display doesn t clear You system may not include a local printer SERVC PT BUS Displays when a problem has occurred with one of the panel s circuits Call your security company ALARM SILENCED This message is added to the scrolling alarm display when alarm sounders are silenced Enter a valid passcode and press ESC or arm the system t...

Страница 49: ...se which allows you to exit after arming an area If you don t exit before the delay time expires entry delay begins You must disarm the Security System Glossary Area A group of detection devices connected to your security system Arm To turn your controlled points burglar detection devices on When an area is armed and a controlled point trips an alarm occurs or entry delay begins When an area is di...

Страница 50: ...ommand center Opening Report A report your system can be programmed to send to the central station indicating that an area has been disarmed Opening and closing reports are commonly used by commercial accounts Perimeter Arm An arming command that arms only the perimeter points Point A detection device or group of devices connected to your security system Points display individually at the command ...

Страница 51: ... use or testing call for service as soon as possible Do not attempt to repair the control panel command centers or detectors yourself How to Clean the Command Center If your command center gets dirty apply a household glass cleaner to a clean cloth or paper towel and wipe the surface Do not spray any liquid directly onto the command center It could run inside the case and damage electrical circuit...

Страница 52: ......

Страница 53: ...S e c u r i t y S y s t e m U s e r s G u i d e ...

Страница 54: ......

Страница 55: ......

Страница 56: ...71 06141 000 B 11 93 ...

Страница 57: ...User s Guides Menu Documents by Type Menu Documents by Product Menu Main Menu ...

Отзывы: