The curve configuration screen has the following configurable options:
•
Name
- Name for the curve. Only 3 characters are possible.
•
Type
- Type of curve: Options are
Standard
and
Custom
o
Standard
- Horizontal axis points are fixed values based on the number of points. Vertical axis points
are adjustable.
o
Custom
- Both horizontal and vertical axes are adjustable.
•
Count
- number of points in the curve. Press the
[Enter]
button to modify the number of points. Long-
pressing the
[Enter]
button will give the following additional options:
o
Preset
- Allows you to set the curve to one of the preset slope values (-45 to 45 degrees in 15 degree
increments). The curve will have 5 points, and smoothing is not enabled by default.
o
Mirror
- Mirrors the selected curve.
o
Clear
- Clears all curve values from the selected curve.
•
Smooth
- When enabled, connects the points with curved lines instead of straight lines.
Editing Curve Points
Editing Curve Points pop-up
After the last configuration option (Smooth), you will automatically begin to scroll through the configured
points on the curve. To change the values of the points, press the
[Enter]
button and then adjust the values
as desired. For
Standard
curves, you will only be able to adjust the Y value. For
Custom
curves, you can
adjust both the X and Y values.
5.
Logical Switches
6.1. Using Logical Switches
Logical Switches are virtual two-position switches whose values (ON/OFF or +100/-100) are based on the
evaluation (true/false) of a defined logical expression. Once configured, logical switches can be used
anywhere in EdgeTX that a physical switch can be defined.
The
Logical Switches
page shows you all the configured logical switches as well as an overview of their
configured options.
Logical Switches Screen
Selecting a logic switch will give you the following options:
•
Edit
- Opens the Logical Switches configuration page for the selected logical switch.
•
Copy
- Copies the selected logical switch
•
Paste
- Pastes a copied logical switch onto the selected logical switch. Note: it will overwrite the selected
logical switch.
•
Clear
- Deletes all configuration options for the selected logical switch.
Содержание MT12
Страница 5: ...1 3 Radio overview...