Page
41
of
60
©
2019 Radiocrafts AS
MBUS User Manual (ver 2.01)
MBUS USER MANUAL
Appendix A
Configuration command details
Command
Details
Comments
ASCII
hex
‘A’
0x41
Auto-message Flags / Flag registers.
Argument
Options
Returns
Register #
1-64 (MBUS3)
1-128 (MBUS4)
(none)
Flags
2 or 3 bytes of flags.
See chapter 7 for details on
the flags
Prompt (>)
The automessage flags
are typically used for
setting up automatic two-
way communication.
Please see chapter 7 for
details.
Readback functions:
•
‘O’-command
•
‘o’-command (RAM)
‘a’
0x61
Auto-message Flags / Flag registers. RAM based installation
addresses.
Argument
Options
Returns
Register #
129-132 (MBUS4)
(none)
Flags
2 or 3 bytes of flags.
See chapter 7 for details on
the flags
Prompt (>)
‘B’
0x42
Bind
Argument
Options
Returns
Register #
1-64 (MBUS3)
1-128 + 133-254 (MBUS4)
(none)
M_ID2
M_ID1
0x00-0x7F
0x00-0xFF
(none)
U_ID4
U_ID3
U_ID2
U_ID1
0x00-0xFF
0x00-0xFF
0x00-0xFF
0x00-0xFF
(none)
VER
0x00-0xFF
(none)
DEV
Please refer to MBUS
standard for defined device
types.
Prompt (>)
This command is used on
the master side to bind
slaves to this master as a
part of the Installation and
binding process,
described in chapter 5.
The host MCU must keep
overview of which
registers are available
and not, so that entries
for already installed
slaves are not
unintentionally
overwritten.
Readback functions:
•
‘L’-command
•
‘l’-command (RAM)
‘b’
0x62
Bind. RAM based installation addresses.
Argument
Options
Returns
Register #
129-132 (MBUS4)
(none)
Address
8 bytes slave address.
See Bind for details.
Prompt (>)