50
direction as when they are on the mains power supply. If motors are operating in
opposite directions, great damages to the boiler may result.
1.3
. The minimal distance from flammable materials
-
Ensure the appropriate distance from flammable materials and, if necessary, provide
their protection.
-
The minimal distance from flammable materials is regulated by law – please seek
information from professionals whose profession is heating and chimneys.
-
The minimal distance between the boiler and flue gas discharge pipes from the
materials of low and average flammability rate should be at least 100mm.
-
The minimal distance from easily flammable materials is 200mm and the same
applies to materials of an unknown flammability rate.
Fire hazard!
-
Storing flammable materials and liquids close to the boiler is forbidden.
-
It is mandatory to inform users of the necessary minimal distance between
flammable materials and the boiler.
A …
inflammable
asbestos, stone, building stone,
ceramic wall tiles, terracotta, stucco,
glazed concrete (without organic
additives)
B …
not easily flammable
drywall, glass fibers, and isolation
panels (AKUMIN, IZOMIN,
RAJOLIT, LIGNOS, VELOKS,
HERAKLIT)
C1…
slow burn rate
beech and oak wood, composite
wood, felt, and isolation panels
(HOBREKS, VERZALIT,
UMAKARTA)
C2 …
average burn rate
pine wood, larch wood, and fir
wood, composite materials
C3 …
easily flammable
asphalt, cardboard, cellulose
materials, particleboard, cork,
polyurethane, polystyrene,
polypropylene, polyethylene, floor
fibers