Cleaning and Storage: 

The Probe is the most delicate part of the thermometer.   
Use with care when cleaning the probe to avoid damage.   

a. Allow the lens to fully dry for at least 1 minute. 
b. Keep the unit dry and away from any liquids and direct sunlight. 
c. 

Please use the alcohol swab or the soft cotton moistened with the 70% alcohol to clean the probe lens.

 

d. Clean the probe and probe lens after each use to ensure an accurate reading and avoid cross contamination. 

 

Important Notes: 

1.

 

Make sure the Probe is clean and avoid the smothered with Rubber boat (Protector).   

2.

 

Before the measurement, please stay in a stable environment for 5mins and avoid the exercise, bath for 30minutes. 

3.

 

Remember to keep the temple area clean and away from sweat, cosmetics and scar while taking temperature. 

4.

 

During the measurement, please away from the direct sunshine and wind. 

Changing the Battery:     

It is supplied with one lithium cell (CR2032x1pcs) 

Open the battery compartment by turning the cover 45° clockwise with a coin. 

Remove the battery safety strip with a sharp-pointed 

object. 

Insert a new battery under the metal hook and press down until you hear a “click” sound 

Close the battery cover.   

 

Keep the battery away from children. 

 

  Disposal of the used batteries

Please comply with the local regulation. 

Ref No.

082012 

TH23F Forehead Thermometer 

Thank you for purchasing this Forehead thermometer. This thermometer is   
designed with advance infrared and ambient temperature compensation 
technology for accurate and fast temperature measurements.   
It also has a wide range mode to scan real time temperature.   

 

  Do not use this device for Live & Dead decision or   

Safety related applications.

    

Please consult with doctor if you   

have health concerns. 

Operating Instructions:

 

1

 

Always make sure the probe lens is clean without any damage,   

and the forehead is clean. 

2

 

Power on:

 Press the “ON/MEM” button. 

3

 

Mode selection: 

3.1

 

FOREHEAD Mode:

 The preset mode of thermometer is forehead. The 

thermometer is ready for use after the “

HEAD

” icon stops flashing and two beep sound. 

3.2

 

SURFACE Mode:

 In “

Power On

” mode, press and hold the “ON/MEM” button, then press the “Meas.” button

,

 the ‘

’ icon will 

replace “

HEAD

” icon in the LCD display.     

4

 

Temperature taking:   

Measuring the FOREHEAD temperature: 
 
 
 
 
 

Figure 4.1          Figure 4.2          Figure 4.3

 

Note: Forehead temperature is displayed in Oral Mode. This thermometer 
converts the forehead temperature to display its "Oral equivalent." 

4.1

 

The temporal artery connect to heart via the carotid artery. Forehead 
thermometer is designed to measure the skin surface over the temporal 
artery, the major artery of the head ( Fig.4.1 ).

 

4.2

 

Attach the device to the required measurement location on the forehead 
( Fig.4.2 ).

 

4.3

 

Press the “Meas.” button, and gently scan around the temple area( Fig.4.3 ) , you can select the left side of the left temples or the 
right side of the right temples. Measurement is completed after a long beep is heard. (The time of measurement might be 
between 5~8sec (up to 30sec). That depends on how long the thermometer get the highest temperature of the forehead.)   

 

4.4

 

Measuring temperature under SURFACE mode: 

When you press the “Meas.” button, you will get the temperature immediately 

about 0.6 sec. If you hold down the “Meas.” button, the reading of measurement will be continuous updated. 

(Surface mode 

shows the actual, unadjusted temperatures, which is different from the forehead mode.)

 

    Note

Classification according to IEC 60601-1

Not classified as AP/APG equipment ; Continuous operation equipment. 

5

 

Switching between Celsius(°C) and Fahrenheit(°F): 

To change the LCD from °C to °F: In “

Power Off

” mode, press and hold the “Meas.” button, then press the “ON/MEM” button for 3 

seconds, icon “

°C

” will be switched to icon “

°F

”. You can also use the same process to change the LCD display from 

°F

 to 

°C

6

 

Memory Function:

 Press the “ON/MEM” button to see the temperature stored. This thermometer provides 25 sets memory for the 

measurements. ** Please notice that only the “HEAD” function’s reading will be recorded. (After each measurement, the reading is 
saved into memory.) 

7

 

Power off:

 

Device will automatically shut down after 1 minute pending to extend battery life.

 At 

next power on, it will get back to the default setting of “HEAD” temperature function 

Holding the thermometer too long may cause a higher ambient temperature reading of the probe.   

This could make the body temperature measurement lower than usual.   

Fever Alarm:

   

If the thermometer detects a temperature 

37.5°C (or 99.5°F) under forehead mode, three short beep sound will follow one long beep 

sound to warn the user for potential fever. 

Specifications:

   

 

 

 

 

 

 

 

 

 

 

 
 

 

 

 

 

 

 

 

Troubleshooting: 

Error Message 

Problem 

Solution 

 

Device stabilization in process.

 

 
Wait until 

  stops flashing.

 

 

Battery is low and no more measurements are 
possible.

 

Replace the battery.

 

 

The device showing a rapid ambient temperature 
change.

 

Allow the thermometer to rest in a room for at least 30 
minutes at room temperature: 10°C~40°C(50°F~104°F).

 

 

The ambient temperature is not within the range 
between 10°C and 40°C (50°F~104°F). 

Allow the thermometer to rest in a room at least 30 minutes 
at room temperature: 10°C~40°C(50°F~104°F). 

 

Error 5~9, the system is not functioning properly. 

Unload the battery, wait for 1 minute and repower it. If the 
message reappears, contact the retailer for service. 

 

 

Temperature taken is higher than 42.2°C (108.0°F) 
for forehead mode or 80°C (176°F) for surface 
mode. 

 

 

Temperature taken is lower than 34°C (93.2°F) for 
forehead mode or –22°C (-7.6°F) for surface mode. 

1) For forehead mode, please stay in a stable environment 
for 5mins and avoid the exercise and bath for 30min, then 
make sure the probe lens is clean before take a new 
temperature measurement. 
2) For surface mode, please select target within 
specifications.   

 If a mal-function still exists, please contact the nearest 

retailer. 

 

Device can not be powered on to the ready stage.  Change with a new battery. 

Warranty:   

12 months   

Manufacture Date

as the serial number( please open the battery cover, it is shown on the inside of the device.)   

Ex.SN:E912A000001, the first “E” is External, the second number “9” is the manufacture year 2009, the third and the fourth 
number “12” is the manufacture month, the others is the serial number. 

Note: The thermometer is calibrated at the time of manufacture. If at any time you question the accuracy of temperature 

measurements, please contact the dealers or nearest service address. 

  Please read the instructions for use       

  BF type applied part

** The thermometer is NOT 

water-proof. Please keep the unit 

dry and away from any liquids.

 

 

1. 

Comply with ASTM E1965-98, IEC60601-1, IEC60601-1-2(EMC) standards. 

2. Temperature measurement range: Forehead mode 34~42.2°C (93.2~108°F), Surface mode: -22~80°C (-7.6~176°F) 

3.

 

Accuracy: Forehead mode: ±0.3°C(0.5°F) 

                  Surface mode: ±0.3°C(0.5°F) within 22~42.2°C (71.6~108°F), others ±4% or ±2°C(4°F) whichever is greater.

 

4.Operating Range

10~40°C (50

 o

F ~104

 o

F), the relative humidity < 85% 

5. ** Storage temperature range: It should be stored at room temperature between -20~+50°C, RH

85% 

    Transportation temperature shall be less than 70°C, RH

95% 

 

There is no gender and age limitation for using infrared thermometer. 

  This is not an AP

 

or APG product.

 

Medical Technology Promedt Consulting GmbH 
Add: Altenhofstrasse 80, D-66386 St. Ingbert, Germany 
 
Radiant Innovation Inc. Tel: +886-3-5644185, Fax: +886-3-5644170, E-mail:[email protected]   
Add: 1F, No.3, Industrial East 9

th

 Rd., Science-Based Industrial Park, HsinChu, Taiwan Http://www.radiantek.com.tw 

Note

The information of manufactory is behind the device . (You can see it after removing the rubber protector) 

Отзывы: