1. INSTALLATION
INST
ALLER
1.1.16. OPTIONAL ELECTRICAL
CONNECTIONS - INDIVIDUAL
INSTALLATION
The cables should be inserted inside the boiler
using the cable glands placed under the board.
Make a hole on the cable gland, smaller than the
cable diameter, to make sure that the air cannot
pass through.
To wire the optionals below:
• (SE) EXTERNAL TEMPERATURE PROBE CODE
73518LA
• (TA) ENVIRONMENT THERMOSTAT
• (CR) REMOTE CONTROL OPEN THERM CODE
40-00017
use the terminal placed inside the control panel
as follows:
DANGER
Cut off the voltage from the main switch.
› remove the front casing of the boiler (see
chapter ACCESSING THE BOILER); unscrew the
screws and remove plate “A” (see fig. 1).
› After removing the plate, connect the electrical
cables to terminal “B” (see fig. 1):
· For the external temperature Probe connect
the two non-polarized conductors to the Se-
Se contacts.
· For the environment Thermostat or Remote
control, first remove the bridge on the Ta-
Ta contacts and then connect the two non-
polarized conductors to the Ta-Ta contacts.
After performing these operations, remount plate
“A” and the front casing.
NOTA BENE:
In case of simultaneous presence of external probe
and remote control, the modulation board only sends the external
temperature value to the remote device without using it for
modulation. The communication between board and remote
control takes place independently from the boiler's operating
mode and after establishing the connection, the display shows
the symbol ‘
’.