radiance SC-Plus Скачать руководство пользователя страница 1

 

Installation & Operation Instructions 

Version: SDUM-210628 

SC-Plus 

Outdoor/Commercial Heaters

EN

Panels covered by these instructions are listed in the table below.  

Model 

Power

Size 

Weight

Mounting

Build-in 

thermostat 

receiver

IP Protection

SC1800-Plus

1800W

137*16*12cm 7Kg

Wall/Ceiling

Yes

IP44

SC2400-Plus

2400W

157*16*12cm 8Kg

Wall/Ceiling

Yes

IP44

Содержание SC-Plus

Страница 1: ...mmercial Heaters EN Panels covered by these instructions are listed in the table below Model Power Size Weight Mounting Build in thermostat receiver IP Protection SC1800 Plus 1800W 137 16 12cm 7Kg Wal...

Страница 2: ...epresents a new generation of infrared panel heaters equipped with a built in thermostat receiver inside of the junction box Artcile Number Receiver01 on the backside of the panel It needs to be used...

Страница 3: ...all children should be kept away from the heater unless constantly supervised Do NOT operate the heater in small rooms when occupied by people not capable of leaving the keep out of reach of children...

Страница 4: ...could cause scratches or other irreparable damage Before operating the heater again it must be completely dry 4 2 Using Working Please note that the heater may discolour with use This is due to airbo...

Страница 5: ...ower switch of Receiver01 on double Receiver01 will only be commanded by the Smart controller Note After the paring process and once Receiver01 and Smart 1 0 Smart 1 0Pro Smartplug are paired the pair...

Страница 6: ...s a surface temperature of special attention and mount them out of reach On the left see the drawing of the mounting requirements When installing the space heater to a ceiling or wall please make sure...

Страница 7: ...liking but make sure the distance doesn t exceed the length of the heater Remove the nut form the wall ceiling anchors part E and place the wall ceiling anchors into the drilled wholes Step 3 Place t...

Страница 8: ...nce shall not be liable for any other occurring costs such as installation cost or any other consequential losses however incurred Please note that tampering with or opening the heater in any way will...

Страница 9: ...mum heat output elmin 0 0 kW Single stage heat output and no room temperature control No In Standby mode elSB 0 001 kW two or more manual stages no room temperature control No with mechanic thermostat...

Страница 10: ...Serial number of your Radiance infrared heater is 10 info theheatingcompany co nz www theheatingcompany co nz The Heating Company Ltd 117 Wairau Rd Wairau Valley Auckland 0627 New Zealand...