background image

www.rad

ialeng

.com

OX8

User Guide

Eight Channel • Transformer Isolated • Microphone Splitter

Specifications and appearance are subject to change without notice.

© Copyright 2021, all rights reserved.

Radial Engineering Ltd.

1845 Kingsway Ave., Port Coquitlam, BC V3C 1S9, Canada

Tel: 604-942-1001  •  Fax: 604-942-1010  

Email: [email protected]

www.radialeng.com

True to the Music

Содержание OX8

Страница 1: ...phone Splitter Specifications and appearance are subject to change without notice Copyright 2021 all rights reserved Radial Engineering Ltd 1845 Kingsway Ave Port Coquitlam BC V3C 1S9 Canada Tel 604 9...

Страница 2: ...This page left blank...

Страница 3: ...leng com OX8 DESIGN CONCEPT The Radial OX8 is an eight channel balanced microphone splitter in a compact 1RU package that divides the mic signals three ways to a direct output a direct output with gro...

Страница 4: ...eliminating noise caused by ground loops Once the loop is complete there is the electrical potential for DC voltage to flow through it This potential is caused by the interaction between devices with...

Страница 5: ...Euroblocks terminals Isolated Output The ISOLATED outputs use eight precision audio isolation transformers to decouple the mic signals from the DIRECT outputs This output may be patched to a separate...

Страница 6: ...t 20 000 operations 9 Internal Ground Lift Each channel features an internal switch that by default is set to lifted so the transformer can isolate ground potential voltages It may be used by system d...

Страница 7: ...nation for the Euroblock terminals are clearly marked on the rear panel Referring to the pins on an XLR connector 1 2 3 G G G G Connecting the DB 25 I O The DB 25 connectors on the rear panel use the...

Страница 8: ...ee consoles to an OX8 The MAIN PA console connects to the DIRECT output and the MONITOR console to the auxil iary DIRECT with LIFT output In order to avoid hum and buzz from ground loops these console...

Страница 9: ...at the ISO LATED output for that channel Internal Chassis Ground Lift All Channels All connectors are 100 isolated from the steel chassis allowing chassis and signal ground to be kept separate However...

Страница 10: ...y different types of transformers to handle the different levels Does the OX8 need power to make it work No The OX8 is completely passive Simply plug in and play What is the difference between Radial...

Страница 11: ...endent 10k with Pad on balanced Features Transformer JT MB CPC 1 1 ratio Eclipse MS10 1 1 ratio Shield Dual Faraday MuMETAL can Input Pad 36dB allows line level sources Ground Lift Disconnects XLR pin...

Страница 12: ...y any request for work to be performed under this limited warranty This limited warranty shall not apply if the product has been damaged due to abuse misuse misapplication accident or as a result of s...

Отзывы: