106
EN
27.9 Menu 9.8.9 - Configuring the end points of the
tubular motor
You can use your Troll Comfort DuoFern to configure the end points of a
connected electronic RADEMACHER tubular motor.
◆
[ SET ]
is additionally displayed during the active end point setting
process.
◆
The end point function is only available for RADEMACHER
electronic tubular motors from 2000 onwards.
◆
The end point setting cannot be adjusted for tubular motors con-
nected in parallel.
◆
The end point function is not available when the light function is
activated, see page 103.
The end points will only be stored if:
◆
The tubular motor is allowed to run for at least four seconds before
an end point is reached.
◆
The configuration process is undertaken starting from the end point
that is to be changed.
◆
/
Check the correct setting of the end points direct-
ly after completing the configuration process with
the help of the operating buttons.