49
EN
18.2 Switching times (opening and closing times) [ / ]; brief description
◆
SENSOR (only for closing times [ ] )
The closing time is controlled by a light sensor in
relation to the level of brightness.
In addition, the measured twilight value is linked to
the previously configured closing time. The configured
closing time is interpreted as "latest at xx:xx hours".
1.
Call up the main menu.
18.2.1 Menu 2 - Configuration of opening and closing times [ / ]
2.
Select and open menu 2
[ ]
Switching times.
3.
Activate and confirm the
switching times.
On = Switching times on
OFF = Switching times off
4.
Select and confirm a
switching time block.
If the function is not acti-
vated, proceed at point 5.
1 = The switching time
setting is realised with
a switching time
mode.
2 = The switching time
setting is realised
without a switching
time mode.
■
Example a:
– In winter dusk begins, for example, at approx.
17:00 hours.
– The closing time has been set to 20:00 hours.
– Your roller shutters will close at 17:00 hours.
■
Example b:
– In summer dusk begins, for example, at approx.
22:00 hours.
– The closing time has been set to 20:00 hours.
– Your roller shutters will close at 20:00 hours.
Содержание RolloTron Comfort 1615 45 19
Страница 87: ...87 EN i ...