65
EN
According to DIN EN 13659, it is necessary to determine
that the movement conditions for the shutters are main-
tained in accordance with EN 12045.
◆
The displacement must amount to at least 40 mm
on the lower edge in the rolled-out position with a
force of 150 N in the upwards direction.
◆
In doing so, it must be ensured that the extending
speed of the shutters for the final 0.4 m is less than
0.15 m/s.
i
Exceeding the maximum permissible running time
(KB) may overload and damage the RolloTron Basic
DuoFern 1200.
◆
The maximum permissible running time for a cycle
may not be exceeded when the equipment is in
operation. For this reason, the RolloTron Basic
DuoFern 1200 has a
running time limit (KB)
of four
minutes.
◆
If the running time limit is triggered, then the
RolloTron Basic DuoFern 1200 must be left for at
least 12 minutes to cool down. During this period,
the indicator light flashes rapidly. Full operational
availability is re-established after approx. one hour.