RADEMACHER DuoFern 9494-1 Скачать руководство пользователя страница 1

VBD 663-2-1 (12.20)

EN

DuoFern Multiple Wall Controller 9494-1

Instruction manual for the electrical connection and for commissioning

Item no. 3250 19 74 / Type: 9494 -1 (surface-mounted with battery)

Содержание DuoFern 9494-1

Страница 1: ...VBD 663 2 1 12 20 EN DuoFern Multiple Wall Controller 9494 1 Instruction manual for the electrical connection and for commissioning Item no 3250 19 74 Type 9494 1 surface mounted with battery...

Страница 2: ...nk you for the trust you have placed in us RADEMACHER products have been developed with the greatest possible convenience in mind Having applied uncompromising quality standards and thorough testing w...

Страница 3: ...12 6 Technical specifications 13 7 Safety instructions 14 7 1 Intended use 14 7 2 Improper use 15 7 3 Required expert knowledge of the installer 15 8 Installation 16 8 1 Printing the label insert 16 8...

Страница 4: ...ng the direction of rotation 29 12 Changing the battery 30 13 Erase all settings software reset 31 14 Dismantling 31 15 Simplified EU Declaration of Conformity 32 16 Warranty Terms and Conditions 33 1...

Страница 5: ...read the instruction manuals of the logged on DuoFern devices as well as of the respective connected appliance This manual is part of the product Please store it in an easily accessible place When pas...

Страница 6: ...ngerous situation 2 1 Levels of danger and signal words DANGER This hazard will lead to serious injury or death if not avoided WARNING WARNING This hazard may result in serious injury or death if not...

Страница 7: ...2 Itemisation 1 or a Lists i further useful information Please read the respective manual i i 2 3 Glossary definition DuoFern RADEMACHER radio technology for controlling compatible products HomePilot...

Страница 8: ...abel insert b 1 x Spacer frame c 1 x Frame d 1 x Wall bracket e 1 x Battery type CR2450 Li Mn Not illustrated f 1 x double sided adhesive strip g 1 x Label insert see page 16 h 1 x Instruction manual...

Страница 9: ...9 EN i 4 Front view of the operating unit Symbol Description T1 to T6 Buttons 1 to 6 LED 1 to LED 6 Each button has a red green LED T6 T2 T4 T5 T1 T3 LED 1 3 5 LED 2 4 6...

Страница 10: ...es Six two tone LEDs red green provide information on the respective status of the operation Max number of DuoFern devices A maximum of 8 DuoFern devices can be logged on per button group When logging...

Страница 11: ...r shutters Venetian blinds in jog mode 1 x tap briefly UP briefly DOWN 1 x long UP DOWN tap again STOP STOP Dim light or save interim values 1 x tap 0 to 100 100 to 0 2 x tap go directly to 100 go dir...

Страница 12: ...mode see page 21 Activate the log off mode see page 23 Clear the DuoFern network see page 26 Activate the jog mode see page 27 Software reset see page 31 1 sec 1 sec 5 sec 1 sec Activate the reversal...

Страница 13: ...ent temperature 0 to 40 C Protection class II only for use in dry rooms Dimensions W x H x D 50 x 50 x 12 mm operating unit DuoFern radio technology Transmission frequency 434 5 MHz Transmission power...

Страница 14: ...teries If a battery has been swallowed medical assistance must be requested immediately In case of contact with the skin eyes or mucous membranes there is a risk of burns from the battery acid Take le...

Страница 15: ...the instructions in this manual 7 3 Required expert knowledge of the installer 7 2 Improper use i Using the DuoFern MultipleWall Controller for any other purpose than previously mentioned is not permi...

Страница 16: ...arent cover panel from the operating panel and insert the printed paper into the cover panel Next press the cover panel on to the operating unit until it locks in place i Templates can be found on our...

Страница 17: ...t on the same frequency can cause interference Do not install the DuoFern Multiple Wall Controller in the proximity of powerful radio systems In order to ensure optimal operation the DuoFern Multiple...

Страница 18: ...red installation position 2 Pull the protective film from the adhesive strip provided and stick it on the back of the wall bracket 3 Remove the second protective film and firmly press the wall bracket...

Страница 19: ...attery compartment 8 3 Installation of the DuoFern MultipleWall Controller i 5 Press the space frame onto the operating unit from the back 6 Finally press the operating unit and the frame on to the wa...

Страница 20: ...a specific button group When logging on the individual DuoFern devices are automatically detected by the DuoFern Multiple Wall Controller and the available button groups are displayed Please read the...

Страница 21: ...t up green 4 Tap on the desired available button group to allocate the new DuoFern device to this button group You can use the left or right button The successful assignment is confirmed by the green...

Страница 22: ...ed 7 You can then assign the next channel if the actuator has more channels available 8 Log on the next DuoFern device MorningMood Wellness Rollershutters Pay attention to the LEDs All LEDs will light...

Страница 23: ...tivate the log off mode on the DuoFern Multiple Wall Controller Simultaneously press and hold the buttons 5 and 6 for 1 second LEDs 5 and 6 will flash red 120 sec The log off mode remains active for a...

Страница 24: ...ilot all 6 buttons of the DuoFern MultipleWall Controller can be used to individually trigger scenes To do so it must first be logged on to the HomePilot 1 Open the user interface of the HomePilot and...

Страница 25: ...e registering mode of the DuoFern Multiple Wall Controller 4 Click on the device and assign an individual name if required In addition a graphic symbol can be selected 5 Save the setting MorningMood W...

Страница 26: ...be carried out in order to logout and delete all DuoFern devices see page 31 1 5 sec Activate the clear up Simultaneously press and hold the buttons 1 and 2 for 5 seconds During the clear up period LE...

Страница 27: ...he buttons 2 and 5 for 1 second LEDs 2 and 5 will flash red 2 If there is a switching mode for one of the button groups the according LEDs 1 to 6 will light up green left LED green jog mode is deactiv...

Страница 28: ...ttons enables Venetian blinds slats to be conveniently configured Driving the slats into the end position Press the operating button longer to drive the Venetian blinds into the end position The drive...

Страница 29: ...groups 5 sec Attention The reversal of rotation direction mode only remains active for approx 5 seconds 1 1 sec Simultaneously press and hold buttons 3 and 4 LEDs 3 and 4 will flash red 2 If there is...

Страница 30: ...ive object e g a plastic rod 3 Replace the battery with a battery of the same type CR2450 Pay attention to the correct polarity when inserting a new battery 4 Then insert the operating unit into the w...

Страница 31: ...ing 1 Carry out a software reset to log off all DuoFern devices from the DuoFern Multiple Wall Controller 2 Carefully pull the operating unit and then the frame out of the wall bracket 3 Remove the wa...

Страница 32: ...R Ger te Elektronik GmbH hereby declares that the DuoFern Multiple Wall Controller 9494 1 complies with the Directive 2014 53 EU Radio Equipment Directive The full text of the declaration of conformit...

Страница 33: ...eathering Repairs and modifications by third parties unauthorised persons Use of unsuitable accessories Damage caused by unacceptable excess voltages e g lightning Operational malfunctions caused by r...

Страница 34: ...34 EN i...

Страница 35: ...35 EN i 30 mm 47 mm 17 Cut out label insert...

Страница 36: ...Service Hotline 01807 933 171 Fax 49 2872 933 253 service rademacher de 30 seconds free of charge subsequently 14 cents minute from German fixed line networks and max 42 cents minute from German cellu...