36
EN
14. Automatic mode
The Troll Basic 5602 features three automatic functions:
◆
Automatic timer
◆
Automatic solar function
◆
Automatic dusk function
All of the automatic functions can be combined or individually
enabled or disabled. The status of each automatic function is
indicated by the respective LED.
The automatic timer can only be switched on if a switching
time has been previously set.
14.1 Switch all automatic functions on / off
simultaneously; Auto/Manu switchover
1.
1 sec.
Press and hold the [AUTO/MANU] button
for approx. 1 second.
2.
All previously activated automatic functions will be
simultaneously switched on or off.
3.
Observe the respective LEDs indicating the status of the
automatic functions, see page 15.
4.
Once automatic mode is deactivated, it is only possible to
operate the system manually.