9. Logging DuoFern transmitters on / off
For the DuoFern Tubular Motor Actuator 9471-1 to be operated
with a DuoFern transmitter, you must log each desired transmitter
onto the DuoFern Tubular Motor Actuator 9471-1. You can log
on a maximum of 20 DuoFern transmitters (e.g. DuoFern Manual
Transmitter Standard, etc.).
1.
Switch the desired DuoFern transmitter to log-on/log-off mode
(please refer to the respective instruction manual).
2.
Press the “Connect (log-on
)“ button or the “Disconnect (log-
off
)” button of the DuoFern Tubular Motor Actuator 9471-1.
3.
The actuator then transmits either a log-on or log-off signal.
Log-on / log-off mode remains active for 120 seconds.
4.
If the log-on/log-off process is successful, the STATUS LED will
light up green constantly.
5.
Log on / log off from the next DuoFern transmitter. To do so,
repeat steps 1 to 3 or else terminate the log-on / log-off process.
Observe the STATUS LED
The STATUS LED lights up red if the log-on / log-off process fails,
for example if:
◆
20 DuoFern transmitters have already been logged on
◆
An unsuitable device (e.g. other DuoFern Actuator) is
logged on.
◆
An attempt was made to log off from a DuoFern transmitter
that is not logged on.