Страница 1: ...VBD 623 3 12 20 Item no 3514 02 61 EN DuoFern Universal Actuator 9470 1 1 channel Instruction manual for the electrical connection and for commissioning Type 9470 1 ...
Страница 2: ...you for the trust you have placed in us RADEMACHER products have been developed with the greatest possible convenience in mind Having applied uncompromising quality standards and thorough testing we are proud to be able to present this innovative product to you It s brought to you by all the highly quali fied personnel here at RADEMACHER ...
Страница 3: ...ription of the functions and parameters 15 6 Technical specifications 17 7 Safety instructions 20 7 1 Intended use 20 7 2 Improper use 21 7 3 Expert knowledge required by the installer 22 8 Connecting the DuoFern Universal Actuator 9470 1 22 8 1 Safety instructions for the electrical connection 22 8 2 Important information regarding the electrical connection 24 8 3 Connecting and installing the Du...
Страница 4: ...4 EN Contents i 10 Deleting all settings reset 30 11 Dismantling 30 12 Simplified EU declaration of conformity 31 13 Warranty terms and conditions 31 ...
Страница 5: ...ction manuals of the accessories if available as well as the instructions of the respective con nected appliance This manual is part of the product Please store it in an easily accessible place When passing the DuoFern Universal Actuator 9470 1 on to a third party this manual must be passed on as well Damageresultingfromnon compliancewiththismanualand the safety instructions will void the warranty...
Страница 6: ...dangerous situation 2 1 Levels of danger and signal words DANGER This hazard will lead to serious injury or death if not avoided WARNING WARNING This hazard may result in serious injury or death if not avoided CAUTION This hazard may result in minor or moderate injury if not avoided ATTENTION This hazard may lead to property damage i ...
Страница 7: ...7 EN 2 2 Symbols and depictions used Depiction Description 1 Procedures 2 Itemisation 1 or a Lists i Further useful information Please read the respective manual i ...
Страница 8: ...mpatible products WR ConfigTool RADEMACHERsoftwareforprogrammingtheDuoFernManual Control incl automatic software updates for the DuoFern Manual Control HomePilot The HomePilot is a central controller unit for RADEMACHER radio products ELV Extra low voltage SELV Safety extra low voltage ...
Страница 9: ...9 EN i 3 Included in delivery Included in delivery a 1 x DuoFern Universal Actuator 9470 1 incl antenna b 1 x instruction manual not illustrated a ...
Страница 10: ...s 2 1 4 Pos Symbol Description 1 Control input 230V 50 Hz on off Connection of an external switch button for manual control on site 2 Relay contact K Connection of an electrical appliance 3 Neutral conductor N Connection of the neutral conductor 4 Supply voltage L 230V 50 Hz Connection of the supply voltage 3 ...
Страница 11: ... light status display green flashing constantly lit up brief flashing Connection is active Connection or disconnection was successful Control command received red flashing or permanently lit up Disconnection is active The overload protection has switched off the actuator Connection or disconnection was not successful 7 Disconnect button Logging off from the DuoFern radio network or a DuoFern trans...
Страница 12: ...peration on site Installation and electrical connection The DuoFern Universal Actuator 9470 1 is designed for flush mounting The electrical connection is carried out by means of clamping the connecting cable in the existing spring clip Overload protection When the DuoFern Universal Actuator 9470 1 is overloaded it heatsupandswitchesoff Thisstateisindicatedbytheflashingred LED It is not possible to...
Страница 13: ...ue range Factory setting A B C D E F G 1 Manual operation On Off Dim 2 Unit light mode Unit light mode Light mode 3 Manual mode on off on off off 4 Automatic timer on off on off on 5 Random function 6 Dawn function 7 Automatic dawn function on off on off off 8 Automatic dusk function 9 Automatic dusk function on off on off off 10 Sun function 11 Automatic sun function on off on off off The WR Conf...
Страница 14: ...r Standard DuoFernWall Controller Function Value range Factory setting A B C D E F G 12 Connectivity test 13 Connect with radio code 14 Reset via radio 3 stage 15 Single button operation 16 Stairwell function on off off 17 Stairway time pulse duration 100 ms 3276 s 3 minutes The WR ConfigTool software can be downloaded from our website at www rademacher de Advanced switch off warning for 60 second...
Страница 15: ...ff On Dawn function On Off Automatic dusk function Off On Random function presence simulation The DuoFern Universal Actuator 9470 1 can process random functionswitchingcommands Ifaswitchingcommandisreceived whichistobedelayedbytherandomfunction thenprocessingof the switching command is delayed by up to 30 minutes Duringthedelaytime theindicatorlightontheDuoFernUniversal Actuator 9470 1 flashes gre...
Страница 16: ...airway function on off When the stairway function is active the DuoFern Universal Actuator 9470 1 will switch off the controlled device again after the set stairway time An advanced switch off warning for 60 seconds and with uneven values can optionally be set ...
Страница 17: ... for an external manual switch button on site Input voltage 230 V Ri 200 kW Relay output load contact K Switching voltage 230 V 50 Hz Maximum switching capacity Ohmic load e g bulbs 16 A 3600 W Inductive loads such as fluorescent lamps drives iron core transformers e g for extra low voltage bulbs such as halogen bulbs 8 A 1800 W M ...
Страница 18: ...ations Improper use can lead to serious injuries or property damage Small contact distance µ not suitable for disconnecting the device Do not use the DuoFern Universal Actuator 9470 1 to discon nect the connected appliance DuoFern radio technology Transmission frequency 434 5 MHz Transmission power Max 10 mW Range Indoors approx 30 m Outdoors approx 100 m Depending on the building structure Max nu...
Страница 19: ...ation Permissible ambient temperature range 20 C to 55 C Dimensions W x H x D 48 7 x 45 7 x 19 8 mm Connecting terminals Spring resistance connecting terminals 0 1 mm2 1 5 mm2 for solid conductors 6 Technical specifications ...
Страница 20: ... within the permissible load limits see Technical Specifications The DuoFern Universal Actuator 9470 1 is suitable for connect ing the mains voltage and extra low voltage ELV with basic insulation Operating conditions Only use the DuoFern Universal Actuator 9470 1 in dry rooms A 230 V 50 Hz power supply together with a site provided disconnecting device fuse must be available at the instal lation ...
Страница 21: ...extra low voltage SELV Never use the radio system e g DuoFern radio system and its components for the remote control of devices and systems with increased safety relevant requirements or where there is an accident risk Applications of this kind require additional safety equipment Observe the respective statutory regula tions for the installation of such systems There is a risk to life caused throu...
Страница 22: ...ctuator 9470 1 8 1 Safety instructions for the electrical connection DANGER There is a risk of fatal electric shock when touching electri cal components All connection and installation work must only be carried out in a de energised state Disconnect all phases of the mains power lead and secure it to prevent any reconnection Check that the system is de energised Priortotheelectricalconnection chec...
Страница 23: ...e observe the details in the Technical Specifications see page 18 ATTENTION A defective antenna can lead to malfunctions or failure of the DuoFern Universal Actuator 9470 1 The antenna lead must not be shortened and damaged WARNING WARNING There is a risk of short circuits and fire if the wrong connect ing cable is used Only use solid copper connecting cables with a cable cross section of 1 5 mm2 ...
Страница 24: ...70 1 is intended for flush mounting We recommend installation in a deep 58 mm flush mounted box or in an electronic socket Length of insulation stripped 9 mm All leads must be stripped to 9 mm 8 2 Important information regarding the electrical connection Connection instructions for operating with an external switch button on site When using the control input E you must connect the external switch ...
Страница 25: ... 1 3 Remove the insulation on all leads as specified above and con nect them according to the following connection diagram 4 InserttheDuoFernUniversalActuator9470 1intotheflush mount ed box and lay the connecting cables as well as the antenna in the box 5 Finally install the cover of the flush mounted box and switch on the electricity again 8 3 Connecting and installing the DuoFern Universal Actua...
Страница 26: ...ermany N L PE 230 V 50 Hz N PE L Appliance Control input E Relay contact K Power supply L i External switch button Neutral conduc tor N Required connecting cable and cable cross section for con necting the electrical appliance Ø 1 5 mm2 Only use a solid copper cable with a cross section of 1 5 mm2 ...
Страница 27: ... K L N L 1 2 N 230 V 50 Hz L Relay contact K 230 V 50 Hz Toggle switch Control input E Relay contact K Appliance Installation with toggle switches We recommend replacing the toggle switch with several switch es connected in parallel You can find further circuit examples on our website at www rademacher de ...
Страница 28: ...he DuoFern Universal Actuator 9470 1 3 The DuoFern Universal Actuator 9470 1 then transmits either a log on or log off signal Log on log off mode remains active for 120 seconds 4 If the log on log off process is successful the STATUS LED will light up green constantly 5 Log on log off from the next DuoFern transmitter To do so repeat steps 1 to 3 or else terminate the log on log off process Observ...
Страница 29: ... to the actuator after installation You will find the radio code on the enclosed label and on the rear side of the DuoFern Universal Actuator 9470 1 i Please note that the use of the radio code is limited to 120 minutes after switching on the power supply A detailed description on activating the radio code function can be found in the instruction manual of the DuoFern Manual Control and the HomePi...
Страница 30: ... reset can be carried out to reset the DuoFern Universal Actuator 9470 1 to the default factory settings 11 Dismantling DANGER There is a risk of fatal electric shock when touching electri cal components Disconnect all phases of the mains power lead and secure it to prevent any reconnection Check that the system is de energised 1 Log the DuoFern controller off from the DuoFern network 2 Ensure the...
Страница 31: ...a24 monthwar ranty for new systems that have been installed in compliance with the installation instructions All construction faults material de fects and manufacturing defects shall be covered by the warranty Yourstatutorywarrantyclaimsremainunaffectedbythiswarranty The following are not covered by the warranty Incorrect fitting or installation Non observance of the installation and operating man...
Страница 32: ...r by replacement of the affected parts or by supplying a new replacement unit or one to the same value There is no general extension of the original warranty period by delivery of a replacement or by repair as per the terms of the warranty RADEMACHER Geräte Elektronik GmbH Buschkamp 7 46414 Rhede Germany info rademacher de www rademacher de Service Hotline 01807 933 171 Fax 49 2872 933 253 service...