background image

1

PRODUCT MANUAL

TF31

DUCT-MOUNTED

TIMED FLOW CONTROLLER

IMPORTANT

Installer:

This Manual is the property of the customer and
must be retained with the product for
maintenance and operational purposes.

www.divapor.com

Содержание TF31

Страница 1: ...UAL TF31 DUCT MOUNTED TIMED FLOW CONTROLLER IMPORTANT Installer This Manual is the property of the customer and must be retained with the product for maintenance and operational purposes w w w d i v a...

Страница 2: ...knesses between 206 mm and 246 mm 8 and 9 DESCRIPTION SAFETY WARNINGS Rada products are precision engineered and should give continued superior and safe performance provided 1 They are installed commi...

Страница 3: ...Rates 5 TemperatureRange 5 Connections 5 DIMENSIONS 6 PACK CONTENTS 7 INSTALLATION General 8 Procedure 8 MAINTENANCE General 10 Preventative Precautionary Maintenance 10 Lubricants 10 Maintenance Proc...

Страница 4: ...Warning Continued use of this product in conditions outside the limits listed in this section can severely affect the performance and reduce the effective service life and can present potential risk t...

Страница 5: ...open outlet Temperature Range Suitable for applications requiring water temperatures up to 70 C Connections 15 mm compression Alternatively a 3 4 BSP male parallel thread is available by removing the...

Страница 6: ...6 DIMENSIONS Model Overall Length A Wall Thickness B TF31 1 TF31 2 TF31 3 445 380 340 206 246 142 182 100 140 49 mm 86 mm A B 50 mm Diameter 32 mm Diameter w w w d i v a p o r c o m...

Страница 7: ...es and to confirm that the parts are included 1 x Actuator Assembly Documentation 1 x Product Manual 1 x O Seal 1 x Timed Flow Valve 1 x Valve Mounting Adaptor 1 x Union Assembly 1 x Guide 2 x Locknut...

Страница 8: ...through the hole from the front of the wall having first made sure that the O seal is correctly installed 3 Firmly fix the actuator assembly into the wall using the 1 2 backnut supplied ensuring that...

Страница 9: ...The valve will not function correctly if the water does not flow in the direction indicated 8 Connect inlet and outlet pipework using the compression fittings supplied To commission Rada TF503 Timed...

Страница 10: ...age corrosion etc Maintain or renew as necessary Lubricate applicable components using silicone only based lubricant Lubricants Important Use silicone only based lubricants on this product Do not use...

Страница 11: ...1 62 Actuator Assembly TF31 2 021 63 Actuator Assembly TF31 3 192 69 Union Assembly 555 19 Valve Mounting Adaptor 622 55 Back Nut 624 09 Union Nut 625 22 Lock Nut 631 39 O Seal 868 10 Guide 631 39 021...

Страница 12: ...n no way affected by this guarantee After Sales Service how we can help you We have a network of fully trained staff ready to provide assistance should you experience any difficulty operating your Rad...