Neighbour = RipEX, which can be accessed directly over the Radio channel (not over Ethernet),
i.e. without a repeater. The graph data is stored in files, each file contains 60 samples of all values.
The sampling period can be configured. There are two types of graphs- Overview and Detail.
Overview graphs cover a continuous time interval back from the present, they use relatively long
sampling period. Detail graph is supposed to be used in case of a special event, e.g. an alarm, and
the sampling period is much shorter.
○
Logged Neighbour IP’s
Default = 0.0.0.0
Up to 5 IP addresses of neighbouring units can be set. (Neighbour = RipEX, which can be ac-
cessed directly over the radio channel, i.e. without a repeater). Watched values from these units
are stored in the graph files and can be displayed afterwards.
○
Overview graph sampling period
List box: 1, 2, 4, 12 hours
Default = 12 hours
The 60 samples per graph file result in (depending on the sampling period) 60, 120, 240 or 720
hours in each file. There are 6 files available, so total history of saved values is 15, 30, 60 or
180 days. The Overwiev graph files are organized in a ring buffer. Whenever a new file is opened,
the oldest one is replaced.
○
Detail Graph sampling period
List box: 1, 5, 10, 20 mins
Default = 1 min
The 60 samples per graph file result in 60, 300, 600, 1200 minutes in each file. There are 20
files available. They are organized in a ring buffer. When a new file is opened, the one with
oldest data is replaced. The Detail graph files may not cover a continuous segment of history.
See Detail graph start for details.
○
Detail Graph start
List box: No, Alarm, Single, Continual
Default = No
Detail graph data sampling is started based on selected event from list box:
No
– Detail graph does not start.
Alarm
– if a tickbox in Detail graph column (Settings/Alarm management) is checked, then the
Detail graph file is stored in case of that alarm. Twenty samples prior the alarm event and forty
samples after the alarm event are recorded. When another alarm occurs while a Detail graph
file is opened, the sampling continues normally and no other file is opened.
Single
– a single Detail graph file can be manually started. After Apply here, go to Diagnost-
ic/Graph where a
Start/Stop
button is available
Continual
– Detail graph files are periodically saved in the same way as Overview graph files
are.
Management
•
Parameters
List box: Default, Manual
Default = Default
Default
– Default (recommended) values are set and can not be edited.
Manual
– Values can be set manually.
○
Web server
List box: HTTP+HTTPS, HTTPS, Off
Default = HTTP+HTTPS
Required protocol for configuration web page is set here. If “Off”, configuration web pages are
inaccessible.
For HTTPS either RACOM (default) or your own SSL certificate can be used.
RipEX Radio modem & Router – © RACOM s.r.o.
104
Advanced Configuration
Содержание RipEX 1.12.0
Страница 2: ......
Страница 172: ...RipEX Radio modem Router RACOM s r o 172 Safety environment licensing...
Страница 173: ...173 RACOM s r o RipEX Radio modem Router Safety environment licensing...
Страница 174: ...Fig 10 2 ATEX Certificate RipEX RipEX Radio modem Router RACOM s r o 174 Safety environment licensing...
Страница 175: ...175 RACOM s r o RipEX Radio modem Router Safety environment licensing...
Страница 176: ...RipEX Radio modem Router RACOM s r o 176 Safety environment licensing...
Страница 186: ...186...
Страница 187: ...Appendix C Revision History 187 RACOM s r o RipEX Radio modem Router Revision History...