Fig. 3.4: RJ-45F
Tab. 3.4: Table of Ethernet to cable connector connections
Crossed
cable
Direct cable
Signal
PIN
white - green
white - orange
TX+
1
green
orange
TX-
2
white - orange
white - green
RX+
3
blue
blue
—
4
white - blue
white - blue
—
5
orange
green
Rx-
6
white - brown
white - brown
—
7
brown
brown
—
8
3.4. Analog and Digital Inputs and Outputs
The board of analog and digital inputs and outputs (ADIO module) is designed for :
•
creating 20 mA current loops
•
switching loads supplied with DC and AC current
•
scanning digital signals
Each functional group of terminals is galvanically separated from the rest of the device as shown on
the internal layout diagram for the ADIO module on the image below:
+A OUT 0
+A IN 0
+A OUT 1
+A IN 1
A IN 0, 1
DIN 1
+DIN 1
A OUT 0, 1
DIN 0
D OUT 0
+DIN 0
D OUT 0
D OUT 1
D OUT 1
Analog outputs
Analog inputs
Digital inputs
Digital outputs
Fig. 3.5: Wiring diagrams for analog and digital inputs and outputs
3.4.1. Labelling
Individual terminals of terminal blocks are labelled:
Connector A OUT
- analog outputs
Connector A IN
- analog inputs
Connector D OUT
- digital outputs
Connector D IN
- digital inputs
Wideband modems – PROFI MX160 – © RACOM s.r.o.
12
Connectors
Содержание PROFI MX160
Страница 1: ...Operating manual Wideband modems PROFI MX160 version 1 3 1 12 2009 ...