12 - VBOX II Digital Inputs
The DIGITAL I/O socket contains the two digital inputs for the VBOX II, accessed by connecting to different
combinations of the three pins.
The first digital input is most commonly referred to as the brake trigger input. This input is connected to an internal timer
capture module that is able to record precisely an event time for use in brake distance calculation. This period of time is
called the trigger event time, and is logged as the value in milliseconds between the last GPS sample and the trigger
event. Typically, this will be connected to a pressure switch placed on the brake pedal, however a hand-held brake
trigger is also available to allow the user to record marker events for other purposes.
The second digital input is used to control the VBOX’s logging; a remote logging on/off switch is available for ease of
use and when the front panel switch is not accessible.
VB20SL3
https://en.racelogic.support//Product_Info/VBOX_Data_Loggers/VBOX_II_Range/VBOX_II_User_Guide/12_-
_VBOX_II_Digital_Inputs