INSTRUCTIONS
PIP® 45W INSTALLATION
RAB Lighting is committed to creating high-quality, affordable, well-designed and energy-efficient LED lighting and controls that make it easy for electricians to install
and end users to save energy. We’d love to hear your comments. Please call the Marketing Department at 888-RAB-1000 or email: [email protected]
IMPORTANT
READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE.
RAB fixtures must be wired in accordance with the National Electrical Code and all applicable local codes. Proper grounding is
required for safety. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON
FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED.
WARNING: Make certain power is OFF before installing the fixture. No user serviceable parts inside.
WALL MOUNTING
GROUND MOUNTING
Mount to a weatherproof
Junction Box
and
Cover Plate
(not supplied)
as shown in
Fig.1
.
To ensure weatherproof seal, apply weatherproof silicone sealant
around the edge of the
Junction Box
(not supplied)
. This is
especially important with an uneven wall surface.
1. Secure LED Flood to a 1/2” NPS on
Cover Plate
(not supplied)
.
Seal arm thread using Teflon® tape or silicone sealant.
2. Connect wires as shown in the wiring diagram
Fig.3
.
Use appropriate UL approved wire connectors as required by
code to make electrical splices to fixture leads. Be careful not
to pinch wires.
WARNING: To prevent wiring damage or abrasion, do not
expose wiring to edges of sharp objects.
3. Attach Cover Plate to
Junction Box
(not supplied)
.
4. Aim floodlight in the direction desired and tighten locknut
and
Arm Screw
.
5. Plug all unused holes and seal threads with Teflon tape or
silicone sealant.
Mount to a
Mighty Post
(RAB CAT# MP19)
as shown in
Fig.2
.
To ensure weatherproof seal, apply weatherproof silicone sealant
around the edge of the
Junction Box
(not supplied)
. This is
especially important with an uneven wall surface.
1. Secure LED Flood on
Mighty Post Cap
. Seal arm thread using
Teflon tape or silicone sealant.
2. Connect wires as shown in the wiring diagram
Fig.3
.
and push all wires inside the
Mighty Post
. Use appropriate
UL approved wire connectors as required by code to make
electrical splices to fixture leads. Be careful not to pinch wires.
WARNING: To prevent wiring damage or abrasion, do not
expose wiring to edges of sharp objects.
3. Place
Mighty Post Cap
on the
Mighty Post
4. Aim floodlight in the direction desired and tighten locknut and
Arm Screw
.
Fig. 1
Fig. 2
PIP 45W
Mighty Post Cap
Mighty Post
Cover Plate
(not supplied)
Junction Box
(not supplied)
Arm Screw