RAB LUMINATOR LightAlert! LU300 Скачать руководство пользователя страница 1

LighlA/ert!. 

Important! 

TEST PERIOD LASTS FOR 

MINUTES 

AFTER POWER IS TURNED ON. 

The Luminator has a 5 minute test period to allow a walk test

during daylight.  During this five minute period the unit will turn

lights on for only 5 seconds each time it detects an object in its

Detection Zone.

After the 5 minute test period,  the  Luminator will reset itself

to 

night only 

operation.

For an additional 5 minute test period,  turn power off for

10 seconds,  then back on.

During darkness,  lights will remain on,  after motion ceases,

for the delay period set on the time control dial.

How Does Luminator Work? 

Luminator's infrared sensor "sees" 

small  temperature changes caused 

by the motion of people or cars with­

in  its detection zone and turns on 

lights automatically.  11 welcomes 

visitors and may  deter intruders. 

How long do the lights 

stay on? 

Lights turn off a short time after 

motion in the detection zone stops. 

You  can adjust this time from 

5 seconds up to 1 0 minutes. Since 

the lights are only on when needed, 

Luminator is ex1remely energy 

efficient. 

Can outdoor lights still be 

turned on with the light 

switch? 

Yes.  Luminator can be controlled 

by a conventional indoor switch or 

circuit breaker. Lights can be turned 

on or off  manually at  night  only. 

■ 

Manual Override Mode (to 

keep lights on):  Flip the switch 

"off"" then "on·· again two times 

(off-on-off-on) within 2 seconds. 

■ 

To Resume Automatic Mode:

Flip the switch once (off-on) within

2 seconds, sensor will reset to

Automatic Mode. 

Will  Luminator detect 

animals? 

Luminator may detect  large animals. 

Having animals trigger Luminator can 

help give property a "lived-in" look. 

You limit animal detection by turning 

down the sensitivity knob or by 

placing electrical tape on the lower 

part of  the lens, or both. 

How are Time and 

Sensitivity set? 

Masking 

the lens 

Time and Sensitivity adjustments 

are located on the underside of 

the sensor. To adjust, tum  the 

knob with your fingers. 

■ 

Time:  sets the time from 

5 seconds to  1 O minutes that 

lights will remain on after 

protection zone is vacated. 

■ 

Sensitivity:  increases or 

decreases the responsiveness 

of  the sensor and  its range. 

Specifications: 

Catalog#: 

LS300 or 

LU300 

Switching Capacity: 

300 watts 

5Amps 

Voltage: 

120 volts 

Protection Pattern: 

50'x110

° 

Time Adjustment: 

5 seconds to 

10 minutes 

Lampholders 

Maximum 

one 150 watt 

Par38 lamp 

per lampholder 

Misc.  Fix1ures 

Suitable for 

Wet Locations 

Отзывы: