INSTRUCTIONS
FIELD-ADJUSTABLE TOMO™ INSTALLATION
RAB Lighting is committed to creating high-quality, affordable, well-designed and energy-efficient LED lighting and controls that make it easy for electricians to install
and end users to save energy. We’d love to hear your comments. Please call the Marketing Department at 888-RAB-1000 or email: [email protected]
CLEANING & MAINTENANCE
CAUTION: Be sure fixture temperature is cool enough to touch.
Do not clean or maintain while fixture is energized.
1. Clean acrylic lens with non-abrasive cleaning solution.
2.
Do not open the fixture to clean the LEDs. Do not touch
the LEDs.
TROUBLESHOOTING
1. Check that the line voltage at the fixture is correct.
Refer to wiring directions.
2. Is the fixture grounded properly?
Note:
These instructions do not cover all details or variations in equipment
nor do they provide for every possible situation during installation, operation
or maintenance.
Universal voltage driver permits operation at 120V through 277V,
50 or 60 Hz. For 0-10V dimming, follow the wiring directions as
shown in
Fig. 12.
1.
Connect the black fixture lead to the LINE supply lead.
2.
Connect the white fixture lead to the COMMON supply lead.
3.
Connect the GROUND wire from fixture to supply ground.
4.
Connect the purple fixture lead to the (V+) DIM lead.
5.
Connect the pink fixture lead to the (V-) DIM lead.
6.
Cap the yellow fixture lead, if present. Do NOT connect.
0-10V DIMMABLE WIRING
PINK
LIGHT
FIXTURE
Vaux 12V
YELLOW
GROUND
GROUND
( - ) DIM V
( + ) DIM V
COMMON
LINE
BLACK
WHITE
PURPLE
Fig: 12