FFLED39 INSTALLATION INSTRUCTIONS 

IMPORTANT

READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE

.

 

RAB fixtures must be wired in accordance with the National Electrical Code and all applicable local codes. Proper 

grounding is required for safety. For fixtures weighing more than 10lbs: Do not mount to an outlet cover unless a 

separate splice box is used. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE 

INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT 

AND THE HAZARDS INVOLVED.

 

WARNING: Make certain power is OFF before installing or maintaining fixture. No user serviceable 

parts inside.

Thank you for buying RAB lighting fixtures. Our goal is to design the best quality products to get the job done right.  We’d like to hear your comments. 

Call the Marketing Department at 888-RAB-1000, or email: [email protected]

LOCATION

1.  Seal arm thread using teflon tape or silicone sealant.

 

2. 

Secure the LED Flood to a 1/2” NPS hole in a 

 

junction box or landscape post.

 

3. 

Plug all unused holes and seal threads with silicone.

 

4. 

The swivel arm on the LED Flood allows 180º of 

vertical aiming adjustment depending on mounting 

location. 

 

GUARD OR SHIELD INSTALLATION

Wire Guard and Poly Shield mount with (4) #8-32 

 

Stainless Steel Screws.

 Screws are provided with 

 

accessory. See figure 1 for Guard. See figure 2 

 

for Shield

 

1. Line up guard with pre-existing, pre-drilled holes in 

frame as shown, tighten screws.

GUARD & SHIELD INSTALLATION

 

The Wire Guard and Poly Shield can be mounted on the 

same fixture with (4) #8-32  screws as shown below.

 

Stainless 
Steel 
Screws

Stainless 
Steel 
Screws

Figure 1

Figure 2

WIRING

Universal voltage drivers permit operation at 120V to 

277VAC, 50 or 60 Hz except fixtures factory ordered 

with a 120V photocell (/PC)

1.  Connect the BLACK fixture lead to the 

 

(+) LINE supply lead.

 

2. 

Connect the WHITE fixture lead to the

 

 (-) COMMON supply lead.

 

3. 

Connect the bare copper Ground wire from fixture 

to supply ground.