12
/ 34
User Manual
Rev. 1.0 - 04/12/20
TEX2503TFT
It is strongly recommended to install the rack at least 50 cm from the rear and side
walls in order to allow optimal air flow and ease of maintenance.
50cm
50cm
COLD
HOT
5.1.3 Power supply connections of the device
Prepare the following connection (valid for both functional tests and final
commissioning):
√
Single-phase mains power connector, 230 (-15% / + 10%) Vac.
A conductor section of at least 2.5 mm
2
is recommended.
Internal connector wiring
Note:
to ensure the safety of the operators, prepare the wiring according to the
laws and regulations in the country where this equipment is installed.
Check that the
POWER
switch on the front panel of the
TEX2503TFT
is in the
“
OFF
” position.
Connect the network cable to the appropriate MAINS socket on the rear panel.
Caution:
To avoid the
risk of damaging the equipment
, it is essential that this
is properly earthed. It is mandatory, therefore, to check the efficiency of the earth
connection of your system.